Independent Yaskawa Drive Repair

Yaskawa VFD Repair — GA500, A1000, V1000 & Legacy

Component-level repair of Yaskawa AC drives: GA500, GA800, A1000, V1000, J1000, P1000, Z1000 and the legacy G7, F7, E7 and GPD series. Free evaluation, written quote before any work, 2-year warranty. Ship it to us or drop it off in Lewisville, TX (Dallas–Fort Worth).

Free Evaluation
2-Year Warranty
Rush 24–72h Service
Drop-Off in Lewisville, TX

Current & Legacy Yaskawa AC Drives

From J1000 micro drives to A1000 and GA800 on cranes and conveyors — we repair the power section and control boards, then load-test the drive before it ships.

Current Series

GA500 / GA800 / GA700

Yaskawa's current general-purpose and high-performance drives. Typical failures: IGBT output stage, DC-bus capacitors, cooling fans, control board power supply.

  • GA500 (CIPR-GA50)
  • GA800 (CIPR-GA80)
  • GA700 (CIPR-GA70)
General PurposeHigh Performance
Workhorse VFD

A1000

The most common Yaskawa drive we see — machine tools, cranes, conveyors and process lines. Power board, gate driver, soft-charge circuit and control board repair.

  • CIMR-AU (200V / 400V / 600V)
  • Crane / hoist applications
Closed-Loop VectorAll Frame Sizes
Compact VFD

V1000 / J1000

Compact drives on pumps, fans, packaging and small conveyors. Repair is usually far faster than waiting on a replacement and re-programming.

  • V1000 (CIMR-VU)
  • J1000 (CIMR-JU)
Compact1-ph & 3-ph
Pump, Fan & HVAC

P1000 / Z1000 / iQpump

Variable-torque drives for water, wastewater and building systems. Capacitor, fan and power-section failures from long run hours are the usual cause.

  • P1000 (CIMR-PU)
  • Z1000 HVAC
  • iQpump1000
Pumps & FansHVAC
Legacy VFD

G7 / F7 / E7

Discontinued but still running everywhere. A replacement often means new mounting, wiring and parameters — repairing the existing G7, F7 or E7 keeps the panel as it is.

  • CIMR-G7U
  • CIMR-F7U
  • CIMR-E7U (HVAC)
DiscontinuedRepair Saves Re-Engineering
Older & Special

GPD 515 / G5 / P5 & U1000

Older GPD-series drives and the U1000 matrix converter. Board-level work where spare units are scarce or no longer available.

  • GPD 515 / G5, GPD 506 / P5
  • U1000 matrix converter
LegacyBoard-Level

Yaskawa Drive Faults We Diagnose & Fix

A fault that comes back after a reset usually points to failed hardware. These are the ones we see most often on the bench.

oC / SC — Overcurrent & Short Circuit

Trips the moment the drive runs, even with the motor disconnected? That points to a shorted IGBT or a failed gate driver. We replace the failed devices, not the whole drive.

Uv1 / Uv3 — Undervoltage & Soft-Charge Fault

Uv1 on a healthy supply usually means aged DC-bus capacitors; Uv3 points to the soft-charge (pre-charge) circuit. Capacitor bank and pre-charge repair.

ov — DC Bus Overvoltage

On decel-heavy loads like cranes and centrifuges, repeated ov trips can mean a failed braking transistor or braking circuit. We test and repair the braking section.

oH / oH1 / FAn — Heatsink Overheat

Failed cooling fan, clogged heatsink or a degraded thermistor. We replace fans, re-apply thermal interface, check the sensor and run the drive at load.

GF / LF — Ground Fault & Output Phase Loss

When the motor and cable test good, GF and LF often trace back to a damaged output device or current-sensing circuit inside the drive.

CPF Errors / Dead Keypad

CPF control-circuit faults, a blank keypad or a drive that won't power up. Control board and switch-mode power supply repair, parameters kept where the board allows it.

How Yaskawa Drive Repair Works

You know the price before we start. Nothing is repaired without your approval.

Send or Drop Off

Ship the drive to us from anywhere in the US, or bring it to our shop in Lewisville, TX.

Free Evaluation

Bench diagnosis of the power section and control electronics, usually within 24–48 hours.

Written Quote

Fixed price and turnaround in writing. Approve it, or get the unit back.

Repair & Load Test

Component-level repair, then a load test before return. 2-year warranty on the repair.

Yaskawa Drive Repair in Dallas–Fort Worth

Our repair shop is in Lewisville, TX. If your plant is in the DFW area or North Texas, you can bring the failed drive in yourself — no packing, no freight, no waiting on a carrier.

Customers outside Texas ship to the same address; we repair Yaskawa drives for plants nationwide.

Flexa Systems LLC
860 Hembry St, Suite 401
Lewisville, TX 75057
Phone: (254) 254-0005
Request a quote before you drop off →

How Much Does Yaskawa VFD Repair Cost?

Typical ranges. Your exact price comes in a written quote after the free evaluation. Repair usually costs 40–70% of a new drive.

Yaskawa driveTypical repair cost
J1000 / V1000 (compact)$300 – $700
A1000 / GA500 (mid-range)$600 – $2,000
GA700 / GA800 / G7 / F7 (high-performance)$800 – $3,000

Rush 24–72h service is available for line-down situations. See rush service.

Yaskawa Drive Down?

Send it in or drop it off in Lewisville, TX. Free evaluation, written quote, 2-year warranty. Standard turnaround 5–30 business days, rush available.

Common Questions

Yaskawa VFD Repair — FAQ

Answers to the questions we get most about Yaskawa drive repair.

Which Yaskawa drives do you repair?

GA500, GA700, GA800, A1000, V1000, J1000, P1000, Z1000 and iQpump drives, the legacy G7, F7 and E7, older GPD 515 / G5 and GPD 506 / P5 drives, and the U1000 matrix converter.

How much does Yaskawa VFD repair cost?

Typical ranges: J1000 / V1000 $300–$700, A1000 / GA500 $600–$2,000, GA700 / GA800 / G7 / F7 $800–$3,000. Evaluation is free and you get a written quote before any work. Repair typically saves 30–60% compared to a new drive.

Can I drop off my Yaskawa drive in the Dallas area?

Yes. Our shop is at 860 Hembry St, Suite 401, Lewisville, TX 75057, in the Dallas–Fort Worth area. Call (254) 254-0005 or request a quote first so we expect your unit.

Do you still repair Yaskawa G7, F7 and E7 drives?

Yes. They are discontinued, and replacing them with an A1000 or GA800 often means new mounting, wiring and parameters. Repairing the existing drive keeps the panel as it is. Common repairs are the IGBT output stage, DC-bus capacitors, soft-charge circuit and cooling fans.

My A1000 shows oC even with the motor disconnected. Is it repairable?

Usually, yes. An oC or SC trip with no motor connected almost always means a failed IGBT or gate-driver circuit inside the drive. We replace the failed components and load-test the drive; there is no need to buy a new one.

How long does Yaskawa drive repair take and what is the warranty?

Standard turnaround is 5–30 business days; rush 24–72h service is available for line-down situations. Every repair carries a 2-year parts and labor warranty and is load-tested before it leaves the shop.

Are you a Yaskawa service center?

No. Flexa Systems is an independent repair company, not affiliated with Yaskawa. We repair Yaskawa drives at component level and back the work with our own 2-year warranty.

Yaskawa, iQpump and the drive series names are trademarks of Yaskawa Electric Corporation. Flexa Systems LLC is an independent repair company and is not affiliated with, endorsed by, or authorized by Yaskawa.

Other Brands We Repair & Stock

Don't See Your Equipment? We Repair These Too