📦 Texas-Based Shop & Warehouse
Serving All 50 States with Fast Turnaround 🇺🇸
Parker 690+0015/460/CBS | 15 HP / 11 kW VFD – 460V, IP20, With Brake Switch & System Board
In-Stock or Repaired Fast – Get Back to Production
The Parker 690+0015/460/CBS is a 460V variable frequency drive delivering 11 kW (15 HP). It comes with a **brake switch** and a **system board**, ideal for regenerative or high-inertia loads. Flexa Systems offers both stocked replacements and fast turnaround repairs.
Drive Specifications
- Power Output: 11 kW / 15 HP
- Voltage Rating: 460V (3-phase)
- Enclosure: Chassis/IP20
- Brake Switch: Integrated
- System Board: Installed
- Model: Parker 690+0015/460/CBS
21 Faults We Fix Regularly – Reworded, Not Repeated
These are the most frequently encountered VFD failures we handle in our repair facility – each rephrased to keep your product page fresh for SEO:
- Phase Loss: Missing phase due to incoming power issues or cable damage.
- Excessive Bus Voltage: Caused by fast deceleration or incorrect braking setup.
- Input Sag: Voltage drop at power-up or under load causing resets.
- IGBT Drive Error: One or more output transistors exceeded limit or failed.
- Overtemperature: Internal heat buildup or clogged ventilation triggering thermal alarm.
- Encoder Not Detected: Speed feedback signal interrupted or misconfigured.
- Brake Error: Fault in resistor or brake transistor logic (this model supports brake switch).
- Current Spike: Load demand exceeds limit momentarily, or short circuit on output side.
- Emergency Stop: Safety input triggered or wired incorrectly to STO logic.
- Signal Loss: Analog input drops or fluctuates, commonly on worn-out 10V/24V supplies.
- Comms Failure: Loss of Modbus/Profibus/Devicenet link to external controller.
- Gate Control Fault: Drive cannot properly switch output stage due to logic board issue.
- Overspeed: Feedback or tuning issue causes motor to exceed configured speed.
- Power-Up Lock: Incomplete boot sequence from EEPROM or corrupted firmware.
- Ripple Current Issue: Indicates capacitor degradation or DC bus instability.
- Temp Probe Fault: Incorrect or no reading from heatsink sensor path.
- Short on Motor Side: Drive detects a direct short between output legs or to ground.
- Control Logic Crash: Internal processor or parameter corruption during runtime.
- Weak Auxiliary Output: 10V/24V line underperforms under minor external load.
- Motor Overheat Protection: Triggers when motor’s thermal threshold is crossed.
- High Inertia Trip: Restart fails or faults out on applications with heavy load inertia.
Trust Flexa Systems for Component-Level Accuracy
We go beyond board swaps. Each 690+ repair is done by trained technicians who understand Parker architecture and have access to proper load-testing equipment.
Important Notes
Let us know if you need help validating the brake resistor sizing, keypad compatibility, or firmware revision.
We **supply and service Parker 690+ units**, with most parts and boards in-stock for fast repair or fulfillment.
Note: Specs decoded from official Parker PN documents. If your label shows minor variation, contact us to cross-match.