📦 Shipping from Texas Warehouse
Serving All 50 States | Based in Texas | Units In-Stock & Ready for Fast Turnaround
Parker 690+0015/230/1NS | 15 HP (11 kW) 230V VFD
- Series: 690+ AC Drive
- Power Output: 15 HP (11 kW)
- Input Voltage: 230V ±10%, 50/60Hz
- Enclosure: NEMA 1 (UL Type 1 – general-purpose indoor use)
- Brake Setup: No braking switch fitted (external resistor support not built-in)
- System Board: System control board included
Repairable Faults We Routinely Solve ⚒️
- ⚡ Overvoltage shutdowns from regenerative energy buildup or improper decel profiles
- 🔋 Undervoltage trips when the power supply drops below operating threshold
- 🚨 Overcurrent from shorted outputs, parallel motor loads, or aggressive acceleration
- 🌡️ Heatsink temperature alarms due to restricted airflow or cooling fan issues
- ⛔ Stalled motor protection triggered by excessive load or low current limit settings
- ❌ Brake resistor faults not applicable — this model lacks braking switch hardware
- 🧨 Internal communication problems between logic and power boards
- 📶 COMMS loss from bad cables, EMI interference, or improper parameter settings
- 🛑 STO-related errors — typically traceable to faulty Safe Torque Off circuitry
- 🔁 Internal firmware or logic controller desyncs — we resolve these often
- 🚀 Speed feedback trip alarms from encoder instability or loose sensor wiring
- ⚠️ Current limit exceeded from poorly tuned boost settings or load shocks
- 🔌 24V supply rail voltage drop — usually from external wiring shorts
- ⚡ Phase detection faults — often tied to supply imbalance or PCB damage
- 💥 DESAT (overcurrent) trips from failing IGBT components or power section faults
- 🔄 Ripple voltage errors on DC bus from aging capacitors or uneven input power
- 🛠️ Analog input overrange, wiring fault, or 4–20mA mismatch
- 🐌 Overcurrent at near-zero speed — often caused by high boost parameters
- 🌡️ Motor thermistor trips due to heat buildup or broken temperature feedback loop
Why Flexa Systems?
We specialize in servicing Parker 690+ series drives like the 690+0015/230/1NS. Even though this unit doesn’t have a braking switch, it’s still a workhorse—and when it fails, we’re ready. Our Texas facility handles both repair and replacement services for clients across the U.S. with fast turnaround and expert results.
📌 Important Notes
Please contact us to confirm your exact requirements or verify application compatibility.
Note: Pricing and availability vary depending on unit condition, configuration, and current stock levels.