π¦ Shipping from Texas Warehouse
Β Serving All 50 States | Based in Texas | Units In-Stock & Ready for Fast Turnaround
Parker 690+0015/230/1BS | 15 HP (11 kW) 230V VFD
- Series: 690+ AC Variable Frequency Drive
- Power Output: 15 HP (11 kW)
- Voltage Input: 230V Β±10%, 50/60Hz
- Enclosure: NEMA 1 (UL Type 1 β standard indoor)
- Brake Configuration: Integrated brake power switch (external resistor required)
- System Board: Fitted
Frequent Failures We Repair π§
- β‘ Overvoltage issues caused by large inertia loads, misconfigured regen settings, or open braking circuits
- π Undervoltage during brownouts, phase imbalance, or internal power supply failure
- π¨ Overcurrent triggered by excessive torque demand, shorted motor cables, or shock loads
- π‘οΈ Heatsink overheating due to blocked cooling paths or high ambient temperatures
- π Motor stall alarms under excessive mechanical loads or improperly set stall trip times
- π₯ Brake resistor overload during repeated deceleration cycles without cooldown
- π₯ Brake switch burnout caused by aggressive stop routines or undersized braking paths
- π‘ COMMS timeouts from poor cable routing, electromagnetic interference, or short time settings
- π STO board failure β we can fix these internal safety board errors fast
- π Faulty controller-to-power board communication often caused by internal damage or firmware errors
- π― Speed feedback faults from damaged encoders or misconfigured feedback loops
- β οΈ Current limit exceeded under sudden torque changes or unbuffered starts
- π 24V power drop caused by short-circuited external control hardware
- π» Phase loss detection errors β internal board issues or external fuse failure
- π£ DESAT (instant overcurrent) from faulty switching modules or blown IGBTs
- π VDC ripple excess β bad capacitor bank or unbalanced supply input
- 𧨠Short circuits in braking circuit or current surge in external resistors
- π Overspeed triggered by faulty speed feedback or parameter mismatches
- π Analog input faults from sensor wiring shorts or incorrect signal configuration
- π’ Overcurrent at low speed β typically fixed boost set too high or improper torque tuning
- π‘οΈ Motor overheating from cooling failure, thermistor disconnection, or improper motor match
Flexa Systems Delivers Repairs You Can Trust
Flexa Systems repairs and stocks Parker 690+0015/230/1BS drives for businesses across the U.S. Whether itβs tripping at startup, failing under load, or misfiring on braking β weβll diagnose and restore your drive fast. Our shop is based in Texas, proudly shipping and servicing nationwide.
π Important Notes
Please contact us to confirm your exact requirements or verify application compatibility.
Note: Pricing and availability vary depending on unit condition, configuration, and current stock levels.