Parker 690+0015/230/1BS | 15 HP (11 kW) 230V VFD
- Series: 690+ AC Variable Frequency Drive
- Power Output: 15 HP (11 kW)
- Voltage Input: 230V ±10%, 50/60Hz
- Enclosure: NEMA 1 (UL Type 1 – standard indoor)
- Brake Configuration: Integrated brake power switch (external resistor required)
- System Board: Fitted
Frequent Failures We Repair 🔧
- ⚡ Overvoltage issues caused by large inertia loads, misconfigured regen settings, or open braking circuits
- 🔋 Undervoltage during brownouts, phase imbalance, or internal power supply failure
- 🚨 Overcurrent triggered by excessive torque demand, shorted motor cables, or shock loads
- 🌡️ Heatsink overheating due to blocked cooling paths or high ambient temperatures
- 🛑 Motor stall alarms under excessive mechanical loads or improperly set stall trip times
- 🔥 Brake resistor overload during repeated deceleration cycles without cooldown
- 💥 Brake switch burnout caused by aggressive stop routines or undersized braking paths
- 📡 COMMS timeouts from poor cable routing, electromagnetic interference, or short time settings
- 🛑 STO board failure — we can fix these internal safety board errors fast
- 🔄 Faulty controller-to-power board communication often caused by internal damage or firmware errors
- 🎯 Speed feedback faults from damaged encoders or misconfigured feedback loops
- ⚠️ Current limit exceeded under sudden torque changes or unbuffered starts
- 🔌 24V power drop caused by short-circuited external control hardware
- 🔻 Phase loss detection errors — internal board issues or external fuse failure
- 💣 DESAT (instant overcurrent) from faulty switching modules or blown IGBTs
- 🔁 VDC ripple excess — bad capacitor bank or unbalanced supply input
- 🧨 Short circuits in braking circuit or current surge in external resistors
- 🚀 Overspeed triggered by faulty speed feedback or parameter mismatches
- 📏 Analog input faults from sensor wiring shorts or incorrect signal configuration
- 🐢 Overcurrent at low speed — typically fixed boost set too high or improper torque tuning
- 🌡️ Motor overheating from cooling failure, thermistor disconnection, or improper motor match
Flexa Systems Delivers Repairs You Can Trust