Parker 690 Series VFD Repair & Supply Services

From STO fault repair to DSAT overcurrent diagnostics, Flexa Systems has helped dozens of clients restore operations fast. Based in Texas and shipping nationwide with rush turnaround, diagnostics, and servo support.

Get My Parker 690 Quote

Common Parker Products We Service

Parker VFDs

  • We service and support all Parker 690 series models — no matter the configuration or part number.

Accessory

Whether it’s the main VFD or any supporting accessory, we’ve got you covered with repair and supply for the full Parker 690 ecosystem.

Most Common Parker 690 Faults We Fix

STO – Safety Torque Off

Safe Torque Off board failure. We have fixed many of these — fast turnaround and 100% confidence in restoration.

DESAT (Over I) – Instantaneous Overcurrent

This is a power section internal fault — very common on Parker 690/890. We repair the issue directly at component level.

Overvoltage

Often caused by high inertia loads, faulty brake resistors, or too high input voltage.

Undervoltage

Caused by missing phases, bad supply, or internal damage.

Overcurrent

Too fast accel/decel, shock loads, short circuits, or bad IGBT — we handle all of them.

Heatsink Overtemp

Poor ventilation or cooling — fully repairable with fan and thermal path testing.

Motor Stalled

Can be from load, low boost setting, or bad configuration.

Brake Resistor Overload

High inertia deceleration too often — we can repair & test the full brake circuit.

Brake Switch Failure

Internal switch overload or configuration issue.

Lost COMMS

Timeout or communication board failure — component-level repair available.

COM Error Code N

Bad link between control and power board — firmware issues fixable.

Speed Feedback Fault

Encoder card or wiring issues — we test and repair encoder signal paths.

Current Limit Trip

Triggered by overload or shock load — verified with dynamic tests.

24V Failure

Common from shorted external controls or damaged onboard power supply.

Phase Loss

Missing phase or internal fault — we validate supply and drive response.

DC Link Ripple

Often a bad input phase or damaged capacitor — fully testable in-house.

Brake Short Circuit

Overcurrent on the braking path — we bench test all paths post-repair.

Overspeed

Feedback signal gone rogue — usually encoder card or loop setting error.

Analog Input Error

Wrong range, wiring issues, or short circuit on external signal wiring.

Low Speed Overcurrent

Boost levels set too high or stuck motor — fully resolvable.

Motor Overtemperature

Bad cooling, bad thermistor, or improper VFD settings — we’ve seen and fixed them all.

Why Choose Flexa Systems for Parker Drives?

  • We repair at component level — no board swaps unless needed.
  • Deep knowledge of 690 & 890 series — we've seen all the quirks.
  • Servo + VFD experts — with full encoder/feedback loop diagnostics.
  • 24-month warranty on repairs and test reports included.
  • Same-day diagnostics and fast rush options available.

Successfully Repaired Units

690-431550B0-B00W00-B400 – Successfully addressed a power module issue (Desat fault).
690+0015/460/CBN - Overcurrent damaged.
690PB/0022/400/3/0/0021/US/0/0/0/0/0 – Feedback issue, successfully resolved.
690+0040/500/1BN - Dessat Fault
690PE/0300/500/0021/US/0/0/0/0/B0/0/0 - No power On
690PD/0300/400/0010/GR/0/0/0/SHTTL/0/0/0 - Trips on DESAT over on run command
690PF/0300/230/0011/US/0/0/0/0/0/115/0 - Bus Overvoltage
690+0003/460/1BN – I/O failure: analog input signal was not being read correctly. Successfully repaired.
690PC/0110/400/0021/US - Busted Input, Current Surge
690-233104F1-000P00-B400 - Intermitent trips on overcurrent on power up even with no motor connected.
690-432590D0-B00P00-A400 - Over Current Fault
690PF/0300/230/0011/US - Under Voltage Alarm
690-432230C0-B00W00-B400 - DC Bus Overvoltage
690PC/0110/400/0010/UK/0/0/0/0/B0/0/0 - Corrosion
690+0015/460/CBN/007 - Power supply issue
690PC/0110/500/0011/UK/0/0/0/0/B0/0/008 - Power supply Issues, No power on
690PD/0300/400/0021/US - Power supply was damaged
690PC/0110/400/0021/US/0/0/0/0/B0/0/0 - Shorted Output 
690+0040D/460/1BN - Currrent Surge
690PC/0110/400/0011/UK/0/0/0/0/B0/0/0 - Moisture
690+0040/230/CNN - Blows fuses when powered up
690-432590D0-B00P00-F000 - Torque feedback Issue
690PD/0300/400/0010/UK - Bad IGBT
690PC/0110/400/0010/GR/0/0/0/0/BO/0/0 - Overcurrent
690-432230C0-B00P00-A400 - Mechanical Damage
690+0015/460/1BN - I/O issue, successfully addressed
690PD/0300/400/0010/FR/0/0/0/0/B0/0/0 - Drive shows it is running, No output to motor
690+0040D/460/CBN - I/O issue

This Product Line is Obsolete

Parker 690 drives have not been manufactured in many years. That doesn’t mean you’re out of options. Flexa Systems specializes in legacy equipment — we’ll find the right solution, whether it’s a full repair or supplying a compatible replacement unit.

Our Repair & Supply Process

📞

Free Consult

Call or request RMA

🔍

Diagnostics

Full fault isolation

💼

Quote

Clear pricing upfront

🛠️

Repair

Tested and validated

🚚

Ship

Tracked delivery

48h

Avg Turnaround

24m

Warranty

50

States Served

Need a Parker 690 Series Drive Repaired?

Call +1 (254) 254-0005 or request an RMA online. We'll handle the rest.

📞 Call Now
Updating…
  • No products in the cart.