Parker 690 Series VFD Repair & Supply Services
From STO fault repair to DSAT overcurrent diagnostics, Flexa Systems has helped dozens of clients restore operations fast. Based in Texas and shipping nationwide with rush turnaround, diagnostics, and servo support.
Get My Parker 690 QuoteCommon Parker Products We Service
Parker VFDs
- We service and support all Parker 690 series models — no matter the configuration or part number.
Accessory
Whether it’s the main VFD or any supporting accessory, we’ve got you covered with repair and supply for the full Parker 690 ecosystem.
Most Common Parker 690 Faults We Fix
STO – Safety Torque Off
Safe Torque Off board failure. We have fixed many of these — fast turnaround and 100% confidence in restoration.
DESAT (Over I) – Instantaneous Overcurrent
This is a power section internal fault — very common on Parker 690/890. We repair the issue directly at component level.
Overvoltage
Often caused by high inertia loads, faulty brake resistors, or too high input voltage.
Undervoltage
Caused by missing phases, bad supply, or internal damage.
Overcurrent
Too fast accel/decel, shock loads, short circuits, or bad IGBT — we handle all of them.
Heatsink Overtemp
Poor ventilation or cooling — fully repairable with fan and thermal path testing.
Motor Stalled
Can be from load, low boost setting, or bad configuration.
Brake Resistor Overload
High inertia deceleration too often — we can repair & test the full brake circuit.
Brake Switch Failure
Internal switch overload or configuration issue.
Lost COMMS
Timeout or communication board failure — component-level repair available.
COM Error Code N
Bad link between control and power board — firmware issues fixable.
Speed Feedback Fault
Encoder card or wiring issues — we test and repair encoder signal paths.
Current Limit Trip
Triggered by overload or shock load — verified with dynamic tests.
24V Failure
Common from shorted external controls or damaged onboard power supply.
Phase Loss
Missing phase or internal fault — we validate supply and drive response.
DC Link Ripple
Often a bad input phase or damaged capacitor — fully testable in-house.
Brake Short Circuit
Overcurrent on the braking path — we bench test all paths post-repair.
Overspeed
Feedback signal gone rogue — usually encoder card or loop setting error.
Analog Input Error
Wrong range, wiring issues, or short circuit on external signal wiring.
Low Speed Overcurrent
Boost levels set too high or stuck motor — fully resolvable.
Motor Overtemperature
Bad cooling, bad thermistor, or improper VFD settings — we’ve seen and fixed them all.
Why Choose Flexa Systems for Parker Drives?
- We repair at component level — no board swaps unless needed.
- Deep knowledge of 690 & 890 series — we've seen all the quirks.
- Servo + VFD experts — with full encoder/feedback loop diagnostics.
- 24-month warranty on repairs and test reports included.
- Same-day diagnostics and fast rush options available.
Successfully Repaired Units
690-431550B0-B00W00-B400 – Successfully addressed a power module issue (Desat fault). 690+0015/460/CBN - Overcurrent damaged. 690PB/0022/400/3/0/0021/US/0/0/0/0/0 – Feedback issue, successfully resolved. 690+0040/500/1BN - Dessat Fault 690PE/0300/500/0021/US/0/0/0/0/B0/0/0 - No power On 690PD/0300/400/0010/GR/0/0/0/SHTTL/0/0/0 - Trips on DESAT over on run command 690PF/0300/230/0011/US/0/0/0/0/0/115/0 - Bus Overvoltage 690+0003/460/1BN – I/O failure: analog input signal was not being read correctly. Successfully repaired. 690PC/0110/400/0021/US - Busted Input, Current Surge 690-233104F1-000P00-B400 - Intermitent trips on overcurrent on power up even with no motor connected. 690-432590D0-B00P00-A400 - Over Current Fault 690PF/0300/230/0011/US - Under Voltage Alarm 690-432230C0-B00W00-B400 - DC Bus Overvoltage 690PC/0110/400/0010/UK/0/0/0/0/B0/0/0 - Corrosion 690+0015/460/CBN/007 - Power supply issue 690PC/0110/500/0011/UK/0/0/0/0/B0/0/008 - Power supply Issues, No power on 690PD/0300/400/0021/US - Power supply was damaged 690PC/0110/400/0021/US/0/0/0/0/B0/0/0 - Shorted Output 690+0040D/460/1BN - Currrent Surge 690PC/0110/400/0011/UK/0/0/0/0/B0/0/0 - Moisture 690+0040/230/CNN - Blows fuses when powered up 690-432590D0-B00P00-F000 - Torque feedback Issue 690PD/0300/400/0010/UK - Bad IGBT 690PC/0110/400/0010/GR/0/0/0/0/BO/0/0 - Overcurrent 690-432230C0-B00P00-A400 - Mechanical Damage 690+0015/460/1BN - I/O issue, successfully addressed 690PD/0300/400/0010/FR/0/0/0/0/B0/0/0 - Drive shows it is running, No output to motor 690+0040D/460/CBN - I/O issue
This Product Line is Obsolete
Parker 690 drives have not been manufactured in many years. That doesn’t mean you’re out of options. Flexa Systems specializes in legacy equipment — we’ll find the right solution, whether it’s a full repair or supplying a compatible replacement unit.
Our Repair & Supply Process
📞
Free Consult
Call or request RMA
🔍
Diagnostics
Full fault isolation
💼
Quote
Clear pricing upfront
🛠️
Repair
Tested and validated
🚚
Ship
Tracked delivery
48h
Avg Turnaround
24m
Warranty
50
States Served
Need a Parker 690 Series Drive Repaired?
Call +1 (254) 254-0005 or request an RMA online. We'll handle the rest.
📞 Call Now