Kinetix 300 Repair — Allen-Bradley 2097 Series


Texas-based shop & warehouse serving all 50 states. Component-level Kinetix 300 repair with closed-loop load testing and a 2-year warranty.





Allen-Bradley Kinetix 300 Repair Services


We diagnose and repair Allen-Bradley Kinetix 300 (catalog 2097-) servo drives at the component level—no board swapping. Typical service includes power-stage troubleshooting, control-board repair, firmware/config backup/restore, and closed-loop load testing. Every unit ships with a documented test report and a 2-year warranty.

Kinetix 300 Errors E19 & E39


Seeing E19 or E39 on a Kinetix 300 (2097- series)? Below are common causes we find during evaluation. We repair both issues at the component level and return the unit fully load-tested.

Error E19 — What It Usually Means


Typical contributors:

  • Control-board component faults in the feedback/tach interface path, most common
  • Encoder/feedback wiring input circuit faulty
  • Feedback device faults (encoder/resolver interface, feedback power), not that common
  • Parameter/tuning problems (following error thresholds, loop gains)

Our process: input inspection, harness/feedback verification, control-board repair as needed, parameter review, and closed-loop load testing with motor.

Error E39 — What It Usually Means


E39 often relates to the power stage:

  • DC-bus/precharge anomalies/failure (soft-start path, inrush control, bleeder)
  • IGBT/gate driver faults or rectifier issues
  • Bus capacitance degradation, thermal stress, or solder fatigue
  • Intermittent power wiring/grounding problems

Our process: power-stage diagnostics and component-level repair (IGBTs, drivers, rectifier, precharge), recap where appropriate, then parameter backup/restore and full load test.

Common Kinetix 300 Symptoms We Service


  • Error E19 — velocity/position/feedback-related
  • Error E39 — power/drive-stage/DC-bus related
  • Drive trips/faults (overcurrent, undervoltage, over-temp, precharge, DC-bus)
  • Following error / position loss from feedback or tuning problems
  • EtherNet/IP communication loss, IP conflicts, parameter corruption
  • Thermal/fan failures and blocked airflow causing overheating
  • Power section failures (IGBTs, gate drivers, rectifier, precharge circuits)

Why Flexa Systems


  • Component-level repair for genuine cost savings
  • Load-tested with motor before return
  • Fast turnaround; rush service available
  • Texas-based shop & warehouse, serving all 50 states
  • 2-year warranty on the repair

Supported Kinetix 300 Part Numbers (2097- Series)


We repair and supply the following Kinetix 300 (2097-) drives:

Don’t see your exact 2097- code? We likely support it—contact us.

Process & Turnaround


  1. Free evaluation quote (based on symptoms/photos)
  2. Inbound check-in & fault capture
  3. Component-level repair & recap as needed
  4. Parameter backup/restore & load test
  5. Final QA + 2-year warranty

Turnaround is typically ~10 business days; rush service available. Lead time is sensitive to parts availability—we’ll advise up front.



()