π¦ Shipping from Texas Warehouse
Β Serving All 50 States | Based in Texas | Units In-Stock & Ready for Fast Turnaround
Parker 690+0020C/460/CBS | 20 HP (15 kW) 460V VFD
- Series: Parker 690+ AC Drive Series
- Power Rating: 20 HP (15 kW)
- Voltage Input: 460V (Nominal: 380β460V Β±10%)
- Enclosure: Chassis (IP20) β for use inside electrical panels
- Braking Configuration: Brake power switch fitted (external resistor not included)
- System Board: Installed
Top Faults We Service on This Unit β οΈ
- β‘ DC overvoltage during fast braking or when resistor path is open
- π Undervoltage trips caused by weak or unstable power supply
- π¨ Motor overcurrent from short circuits, improper tuning, or heavy torque spikes
- π‘οΈ Heatsink temperature trips from poor airflow or fan failure
- π Motor stall errors due to underconfigured current limit or excessive load
- π₯ Brake resistor overloads caused by frequent or rapid deceleration
- π£ Brake switch overuse failure β often after high braking duty cycles
- π‘ Communication loss from misconfigured COMMS timeout or damaged cable
- π STO safety input issues or intermittent faults from wiring degradation
- π Control-to-power communication sync errors from firmware instability
- π― Speed feedback faults from encoder signal loss or parameter mismatch
- β οΈ Current limit exceeded under acceleration or torque overshoot
- π 24V power rail undervoltage caused by external short circuit
- β‘ Phase loss trips due to wiring issues or internal damage
- π₯ DESAT (Over-I) β typically means damaged IGBTs or blown gate driver
- π High DC bus ripple due to failing capacitors or missing input phase
- 𧨠Brake resistor circuit trip β usually a wiring error or overload
- π Overspeed alarms from unstable feedback or encoder malfunction
- π Analog input misreadings β sensor failure or incorrect signal mode
- π Overcurrent at low speeds due to misconfigured boost or load jump
- π‘οΈ Motor overtemp protection trips from thermistor failure or cooling problems
Why Flexa Systems?
Flexa Systems provides both repair and replacement for the Parker 690+0020C/460/CBS VFD. Our Texas-based team restores these drives down to the component level. Whether you’re experiencing fault codes, control board failures, or braking issues, weβve got the tools and experience to get it running again β fast and nationwide.
π Important Notes
Please contact us to confirm your exact requirements or verify application compatibility.
Note: Pricing and availability vary depending on unit condition, configuration, and current stock levels.