π¦ Shipping from Texas Warehouse
Β Serving All 50 States | Based in Texas | Units In-Stock & Ready for Fast Turnaround
Parker 690+0001/460/CBNF | 1 HP (0.75 kW) 460V VFD
- Series: 690+ AC Frequency Drive
- Power Output: 1 HP (0.75 kW)
- Voltage Input: 460V (Supports 380β460V Β±10%)
- Enclosure: Chassis mount (IP20), ideal for cabinet integration
- Braking Setup: Includes braking power switch (external resistor not included)
- System Board: Not present
We Fix These Common Failures on This Model π
- β οΈ Overvoltage from oversized loads, regen energy with no brake resistor, or high supply input
- π Undervoltage issues from phase loss, line instability, or control board faults
- π¨ Overcurrent from short circuits, load spikes, or poorly set boost parameters
- π₯ Heatsink over-temp due to poor airflow or overheating cabinet conditions
- π Motor stall errors caused by excessive load or too-low current limit settings
- π₯ External brake resistor overload during abrupt or frequent stopping cycles
- 𧨠Internal brake switch trip from aggressive deceleration profiles
- π‘ Communication loss caused by bad cabling, improperly set COMMS timeout, or damaged ports
- π STO safety faults β often due to defective STO board components
- π Comms error between logic board and power section β usually solvable with firmware or board repairs
- π Speed deviation errors from encoder feedback issues
- β‘ Current limit exceeded during fast starts, torque bursts, or wrong ramp settings
- π 24V output drop from overload or shorts in customer wiring
- β οΈ Phase detection faults indicating missing phase or damaged internal components
- π£ DESAT faults caused by blown IGBTs or shorted drive stages
- π Ripple voltage instability from DC bus capacitor aging or input phase mismatch
- π§ Brake circuit faults due to shorted or improperly wired braking path
- π Overspeed conditions often from failed encoder feedback or configuration mismatch
- ποΈ Analog input misreadings due to miswiring or mode conflict
- π Low-speed overcurrent from overboosting or failed motor wiring
- π‘οΈ Motor overheating due to failed thermistor feedback or prolonged low-RPM usage
Why Flexa Systems?
Flexa Systems offers premium repair and replacement services for the Parker 690+0001/460/CBNF VFD. Whether you’re seeing cryptic error codes, odd startup behavior, or just no output at all β our experienced technicians can diagnose and resolve it quickly. Based in Texas and serving all of the U.S., we keep your operations running smoothly and efficiently.
π Important Notes
Please contact us to confirm your exact requirements or verify application compatibility.
Note: Pricing and availability vary depending on unit condition, configuration, and current stock levels.