Parker 690+0001/460/CBNF | 1 HP (0.75 kW) 460V VFD
- Series: 690+ AC Frequency Drive
- Power Output: 1 HP (0.75 kW)
- Voltage Input: 460V (Supports 380–460V ±10%)
- Enclosure: Chassis mount (IP20), ideal for cabinet integration
- Braking Setup: Includes braking power switch (external resistor not included)
- System Board: Not present
We Fix These Common Failures on This Model 🔍
- ⚠️ Overvoltage from oversized loads, regen energy with no brake resistor, or high supply input
- 🔋 Undervoltage issues from phase loss, line instability, or control board faults
- 🚨 Overcurrent from short circuits, load spikes, or poorly set boost parameters
- 🔥 Heatsink over-temp due to poor airflow or overheating cabinet conditions
- 🌀 Motor stall errors caused by excessive load or too-low current limit settings
- 💥 External brake resistor overload during abrupt or frequent stopping cycles
- 🧨 Internal brake switch trip from aggressive deceleration profiles
- 📡 Communication loss caused by bad cabling, improperly set COMMS timeout, or damaged ports
- 🛑 STO safety faults — often due to defective STO board components
- 🔁 Comms error between logic board and power section — usually solvable with firmware or board repairs
- 📉 Speed deviation errors from encoder feedback issues
- ⚡ Current limit exceeded during fast starts, torque bursts, or wrong ramp settings
- 🔌 24V output drop from overload or shorts in customer wiring
- ⚠️ Phase detection faults indicating missing phase or damaged internal components
- 💣 DESAT faults caused by blown IGBTs or shorted drive stages
- 📈 Ripple voltage instability from DC bus capacitor aging or input phase mismatch
- 🚧 Brake circuit faults due to shorted or improperly wired braking path
- 🚀 Overspeed conditions often from failed encoder feedback or configuration mismatch
- 🎚️ Analog input misreadings due to miswiring or mode conflict
- 🐌 Low-speed overcurrent from overboosting or failed motor wiring
- 🌡️ Motor overheating due to failed thermistor feedback or prolonged low-RPM usage
Why Flexa Systems?
Flexa Systems offers premium repair and replacement services for the Parker 690+0001/460/CBNF VFD. Whether you’re seeing cryptic error codes, odd startup behavior, or just no output at all — our experienced technicians can diagnose and resolve it quickly. Based in Texas and serving all of the U.S., we keep your operations running smoothly and efficiently.