📦 Shipping from Texas Warehouse
Serving All 50 States | Based in Texas | Units In-Stock & Ready for Fast Turnaround
Parker 690+0001/460/CBN | 1 HP (0.75 kW) 460V VFD
- Series: 690+ AC Drive
- Power Output: 1 HP (0.75 kW)
- Input Voltage: 460V (Range: 380–460V ±10%)
- Enclosure: Chassis (IP20) — ideal for integration inside enclosures
- Brake Configuration: Brake power switch included (external resistor not included)
- System Board: Not included
Repairs We Perform on This Model 🔧
- ⚡ High voltage trips due to overloaded motors, config errors, or open brake resistors
- 🔋 Low voltage trips from missing phases, poor input power, or internal board faults
- 🚨 Excessive motor current draw during startup or braking — possibly due to shorts or shock loading
- 🌡️ Overheat shutdowns from blocked airflow, high ambient temps, or fan failures
- ⛔ Stalled motors due to boost settings or incorrect load configurations
- 🔥 Dynamic brake resistor overloads from rapid or repetitive deceleration
- 🧨 Faulty brake switch components under stress from high-inertia stops
- 🔗 Loss of communication with external controllers — usually misconfigured timeout or wiring
- 🛡️ STO board errors — often related to damaged circuitry or improper board seating
- 📉 Speed feedback drift or mismatch leading to instability in closed-loop control
- ⚠️ Overcurrent faults from aggressive acceleration profiles or shorted wiring
- 🧃 24V output low — traced back to shorts or excessive load on the customer terminals
- 💡 Phase detection faults — either a genuine phase loss or internal trace issue
- 🔥 DESAT error — an overcurrent protection trip usually tied to IGBT damage
- 🔄 High ripple on the DC bus due to missing phases or faulty capacitors
- 💥 Brake resistor circuit faults caused by overcurrent events
- 🚀 Overspeed alerts — often caused by encoder miscalibration or mechanical instability
- 📟 Analog signal range errors or misconfigurations on 4-20mA input
- 🐌 Drive pulling too much current at low frequency — often due to overboosting
- 🔥 Motor thermal protection tripped due to sustained low-speed operation or thermistor break
- 🔄 Controller comms faults from firmware instability or damaged control cards
Why Flexa Systems is the Right Choice
At Flexa Systems, we bring Parker 690+ drives like the 690+0001/460/CBN back to life with expert testing and component-level repair. Whether it’s a feedback issue, braking problem, or total startup failure — we’ve got you covered. Located in Texas, we support clients across all 50 states with fast shipping and dependable turnaround.
📌 Important Notes
Please contact us to confirm your exact requirements or verify application compatibility.
Note: Pricing and availability vary depending on unit condition, configuration, and current stock levels.