π¦ Shipping from Texas Warehouse
Β Serving All 50 States | Based in Texas | Units In-Stock & Ready for Fast Turnaround
Parker 690+0001/460/CBN | 1 HP (0.75 kW) 460V VFD
- Series: 690+ AC Drive
- Power Output: 1 HP (0.75 kW)
- Input Voltage: 460V (Range: 380β460V Β±10%)
- Enclosure: Chassis (IP20) β ideal for integration inside enclosures
- Brake Configuration: Brake power switch included (external resistor not included)
- System Board: Not included
Repairs We Perform on This Model π§
- β‘ High voltage trips due to overloaded motors, config errors, or open brake resistors
- π Low voltage trips from missing phases, poor input power, or internal board faults
- π¨ Excessive motor current draw during startup or braking β possibly due to shorts or shock loading
- π‘οΈ Overheat shutdowns from blocked airflow, high ambient temps, or fan failures
- β Stalled motors due to boost settings or incorrect load configurations
- π₯ Dynamic brake resistor overloads from rapid or repetitive deceleration
- 𧨠Faulty brake switch components under stress from high-inertia stops
- π Loss of communication with external controllers β usually misconfigured timeout or wiring
- π‘οΈ STO board errors β often related to damaged circuitry or improper board seating
- π Speed feedback drift or mismatch leading to instability in closed-loop control
- β οΈ Overcurrent faults from aggressive acceleration profiles or shorted wiring
- π§ 24V output low β traced back to shorts or excessive load on the customer terminals
- π‘ Phase detection faults β either a genuine phase loss or internal trace issue
- π₯ DESAT error β an overcurrent protection trip usually tied to IGBT damage
- π High ripple on the DC bus due to missing phases or faulty capacitors
- π₯ Brake resistor circuit faults caused by overcurrent events
- π Overspeed alerts β often caused by encoder miscalibration or mechanical instability
- π Analog signal range errors or misconfigurations on 4-20mA input
- π Drive pulling too much current at low frequency β often due to overboosting
- π₯ Motor thermal protection tripped due to sustained low-speed operation or thermistor break
- π Controller comms faults from firmware instability or damaged control cards
Why Flexa Systems is the Right Choice
At Flexa Systems, we bring Parker 690+ drives like the 690+0001/460/CBN back to life with expert testing and component-level repair. Whether itβs a feedback issue, braking problem, or total startup failure β weβve got you covered. Located in Texas, we support clients across all 50 states with fast shipping and dependable turnaround.
π Important Notes
Please contact us to confirm your exact requirements or verify application compatibility.
Note: Pricing and availability vary depending on unit condition, configuration, and current stock levels.