Parker 690+0001/230/1BS | 1 HP (0.75 kW) 230V VFD
- Series: 690+ AC Drive
- Power Rating: 1 HP (0.75 kW)
- Input Voltage: 230V ±10%, 50/60Hz
- Enclosure Type: NEMA 1 (UL Type 1 – indoor rated)
- Braking Configuration: Integrated brake power switch (resistor not included)
- System Board: System board fitted
Common Drive Issues We Can Fix 🔧
- ⚡ Excessively high internal voltage (DC overvoltage) caused by large loads, poor config, or faulty resistors
- 🔌 Undervoltage from missing phases, unstable supply, or internal hardware issues
- 🔁 Drive overcurrent due to shock loads, short circuits, or improper motor setups
- 🌡️ Overheated heatsink due to poor spacing or blocked airflow in control panels
- 🚫 Motor fails to start or rotate due to misconfiguration or excessive load
- 🔥 Braking resistor overload during frequent or rapid deceleration events
- 🧨 Internal brake switch damage from repeated high-inertia braking
- 📶 Lost communication due to misconfigured timeout settings or cable faults
- 🛑 STO (Safe Torque Off) failure—often a damaged or degraded STO board
- 🔄 Controller to power board comm failure—likely internal firmware or logic board damage
- 📉 Speed feedback errors beyond 50% deviation for over 10 seconds
- 🚨 Trips from current limit spikes over 180% due to rapid acceleration/deceleration
- 🔋 24V output drop below 17V, usually from shorts or excessive draw
- ⚠️ Phase failure: one or more power phases missing, fuse blowouts, or internal trace damage
- 💥 Instant overcurrent (DESAT), commonly linked to failing IGBTs or drive stages
- 📈 DC ripple voltage too high from poor phase balance or faulty bus capacitors
- 💣 Brake short circuit — brake path drawing excess current
- 🚀 Overspeed detection from encoder misfeedback or faulty speed control
- 🎚️ Analog input errors — often wiring issues or misconfigured input ranges
- 🐌 High current at low speeds — boost settings too high or internal failures
- 🔥 Motor overheating caused by thermistor wiring issues, prolonged low-speed use, or incorrect voltage rating
Why Choose Flexa Systems?
Flexa Systems offers expert repair and stock services for the Parker 690+0001/230/1BS and other VFDs in the 690+ series. From diagnosing common faults to sourcing quality-tested replacements, our Texas-based operation serves clients across all 50 U.S. states. Whether you need a unit repaired, refurbished, or replaced — we’re here to deliver fast, reliable results.
📌 Important Notes
Please contact us to confirm your exact requirements or verify application compatibility.
Note: Pricing and availability vary depending on unit condition, configuration, and current stock levels.