ALLEN BRADLEY

Allen-Bradley 2097-V34PR6 | Repair & Stock

Brand new, original packaging:
$ 3820
In stock: 1
Refurbished price:
$ TBD
In stock: 1
Repair Price Standard:
$ 1610
Make the order
Request repair
Field Service Request
Call +1 (254) 254-0005 for a Quote
Delivery
Estimated delivery time for selling products 3-10 days.
Regular repair estimated turnaround time 5-20 days.
Hot rush repair turn around time 1-5 days.
📦 Texas-Based Shop & Warehouse
Serving All 50 States with Fast Turnaround 🇺🇸

Allen-Bradley – 2097-V34PR6 | 480V 3-Phase / 8.5A Servo Drive

Quick Repair or Stocked Unit – We’ve Got You Covered

When your Kinetix 300 drive model 2097-V34PR6 fails, don’t wait. At Flexa Systems, we provide precision component-level repairs, fast turnarounds, and even replacement units when needed — all backed by a 2-Year Warranty.


Key Specifications

  • Catalog Number: 2097-V34PR6
  • Drive Series: Kinetix 300
  • Input Voltage: 480V AC, 3-Phase
  • Continuous Output Current: 8.5 A
  • Safety Feature: Safe Torque Off (STO) Supported
  • Mounting: Panel-mount with IP20 Protection (enclosed)
  • Communication: EtherNet/IP indexing with motion support

Drive Configuration

While Allen-Bradley doesn’t use part-number-based configuration like some brands, the 2097-V34PR6 includes:

  • Compatibility with CompactLogix™ and ControlLogix® systems
  • Fully integrated EtherNet/IP motion control
  • 24V DC backup input available for critical uptime scenarios
  • Robust STO circuit support for functional safety compliance

Most Common Faults We Handle

  • Overvoltage: Often caused by supply surges or regen braking without proper dissipation.
  • Undervoltage: Typically results from power sag or missing input phase.
  • Overcurrent: Frequently linked to motor shorting or acceleration ramp misconfiguration.
  • STO Faults: Internal STO board or connector issues — very common on this series.
  • Loss of Communication: Damage to EtherNet/IP ports, EMI, or grounding issues.
  • Current Limit / Desaturation: Indicative of IGBT failure or stress on the power section.
  • Feedback Errors: Encoder/resolver wiring faults or shielding problems can trigger this.

Each unit undergoes full diagnostic testing, part-level replacement, and real-world simulated load testing before we ship it back to you.

Why Do These Fail?

Over the years, we’ve found the most common reasons for 2097-V34PR6 failures to be:

  • High-voltage transients on the mains due to poor power quality or switching noise
  • Motor insulation breakdown or winding faults feeding destructive energy back to the drive
  • Improper cable routing or weak shielding leading to feedback and STO signal faults

Important Notes

Not sure if the 2097-V34PR6 is the exact match for your application? Just contact us or send a photo of your existing label — we’ll match it and assist with replacement or repair.

At Flexa Systems, we don’t just fix drives — we restore reliability. From full rebuilds to stocked spares, we support every Kinetix 300 model in-house. Every unit comes with Texas-based service and nationwide shipping.

Note: Specs and details are for general guidance. Please verify all compatibility data before installation.

Manufacturer

ALLEN BRADLEY

Flexa-Systems LLC is not officially linked as a dealer, agent, or affiliate of any designers, brands, or manufacturers whose products are showcased on www.flexa-systems.com. Any mentioned trademarks, brand names, or logos serve solely for identification purposes and remain the registered trademarks of their respective owners, who maintain their rights. The inclusion of these trademarks, brand names, or products on our website does not imply any affiliation or endorsement by the company, trademark, or brand."

Flexa Systems' (2) Year Limited Warranty

Our Warranty
Flexa Systems LLC offers a comprehensive warranty program to ensure peace of mind for your industrial equipment investments. Limited Warranty Coverage
  • Equipment Repairs:
    We provide a 2-year limited warranty on all industrial equipment repairs performed by our technicians. This warranty demonstrates our commitment to the quality of our workmanship. If a repaired item fails due to a covered defect, we will re-repair it free of charge.
  • New Equipment Sales:
    New equipment carries the original manufacturer's warranty. We will gladly facilitate warranty processes with the manufacturer on your behalf.
  • Refurbished Equipment Sales:
    Refurbished equipment comes with a 2-year limited warranty from Flexa Systems LLC, covering defects in materials and workmanship related to our refurbishment process.
Warranty Exclusions (Applies to both repair and refurbished equipment warranties)
This warranty does not cover:
  • New damage caused by liquid, dust, or object contamination
  • New damage caused by mechanical impact, improper installation, incorrect accessories, voltage or current issues, overloading, or overheating.
  • Severe scratches on the unit
  • Broken display (if applicable)
  • Impact or dropping of the unit
  • Removal or deterioration of the warranty sticker
  • Opening the product's cover (if applicable)
Warranty Claim Process
To initiate a warranty claim, please contact our customer support team. Repair or replacement under warranty can take up to 31 calendar days.
Important Note: We repair industrial equipment from various brands; however, we are not a dealer, agent, or affiliate of any specific designers, brands, or manufacturers.
SKU: 35002 Categories: , Brand: ,
Updating…
  • No products in the cart.