📦 Shipping from Texas Warehouse
Serving All 50 States | Based in Texas | Units In-Stock & Ready for Fast Turnaround
Parker 690+0010/460/1BN | 10 HP (7.5 kW) 460V VFD
- Series: 690+ AC Drive
- Power Output: 10 HP (7.5 kW)
- Input Voltage: 460V (Accepts 380–460V ±10%)
- Enclosure Type: NEMA 1 (Indoor-rated, UL Type 1)
- Braking Feature: Brake switch included, external resistor required
- System Board: Not included
Repairable Issues Common on This Drive 🔧
- ⚡ DC link overvoltage due to regen energy buildup, high input, or missing brake resistor
- 🔋 DC undervoltage during power dips, phase loss, or internal PSU failure
- 🚨 Motor overcurrent events caused by shock loading or wrong torque/ramp settings
- 🌡️ Heatsink thermal trips — often from blocked vents or control cabinet overheating
- 🐢 Motor stall trips from load inertia, poor torque config, or low current limits
- 🔥 Overloaded braking resistor in heavy decel applications without proper delay
- 🧨 Brake switch overload under frequent stops or long decel profiles
- 📡 Communication dropout due to bad cable routing or COMMS config
- 🛑 STO error tied to safe torque off module failure or board damage
- 🔄 Internal COMMS failure between controller and IGBT modules
- 🎯 Encoder or feedback mismatch, causing speed regulation faults
- ⚠️ Current spikes tripping the drive when exceeding set threshold
- 🔌 24V output supply drop triggered by shorts in the customer interface
- ⚠️ Input phase fail warning — may be due to wiring, fusing, or internal trace issues
- 💥 DESAT protection triggering from IGBT or power transistor faults
- 🔁 High VDC ripple warnings from unbalanced input or weak bus caps
- 💣 Brake circuit overcurrent fault, indicating bad wiring or resistor failure
- 🚀 Overspeed alarms due to faulty encoder or unstable feedback loop
- 📏 Analog input configuration error or signal drift
- 🐌 Excess current at low frequency, typically from fixed boost misconfiguration
- 🌡️ Motor overtemp detection caused by failed thermistor or poor ventilation
Flexa Systems — Parker Drive Specialists
We stock and service the Parker 690+0010/460/1BN for clients nationwide. Whether your VFD is locking up, tripping with faults, or not powering up at all — we can help. Flexa Systems offers fast, dependable service from our Texas facility, with nationwide support and quick turnaround.
📌 Important Notes
Please contact us to confirm your exact requirements or verify application compatibility.
Note: Pricing and availability vary depending on unit condition, configuration, and current stock levels.