Parker 690+0007/230/1BS | 7.5 HP (5.5 kW) 230V VFD
- Series: 690+ AC Variable Frequency Drive
- Power Output: 7.5 HP (5.5 kW)
- Input Voltage: 230V Β±10%, 50/60Hz
- Enclosure: NEMA 1 (UL Type 1) for standard indoor environments
- Brake Setup: Integrated brake switch (resistor must be ordered separately)
- System Board: Supplied with system control board
Common Faults We Can Professionally Repair π
- π Overvoltage during braking or regen cycles β likely due to resistor circuit issues or config mismatch
- π Undervoltage from phase loss, poor incoming power, or defective drive components
- π¨ Overcurrent tripping caused by improper motor setup, shorts, or aggressive acceleration
- π‘οΈ Heatsink over-temp alarms resulting from poor panel airflow or fan failure
- π Stall detection triggering due to incorrect boost settings or excessive mechanical load
- π₯ Brake resistor thermal overload from frequent high-torque stopping
- π₯ Brake switch component degradation due to inertia loads or under-configured decel profiles
- πΆ Comms timeout from incorrectly set parameters or broken signal wiring
- π§― STO safety trip β this can indicate a faulty STO module or connection
- β‘ Internal comms failure between boards β often fixed with firmware or logic board repairs
- π Speed feedback errors over tolerance β typical in encoder misalignment or sensor issues
- π Current limit trips from unexpected torque spikes or load fluctuation
- π‘ 24V control circuit drops due to shorts or overdraw in the external system
- β οΈ Phase fail detection from open fuses or miswiring β or internal drive PCB faults
- β‘ DESAT fault indicating power transistor or IGBT trouble β common in high-torque applications
- π VDC ripple trips β caused by missing input phases or aged DC link capacitors
- π οΈ Brake circuit current trips (short or overload) traced to wiring or resistor failure
- π Overspeed trips triggered by feedback instability or faulty speed control circuits
- π Analog input misreadings due to wiring damage or signal mode conflicts
- π Excess current at low speed due to overly aggressive boost or drive config
- π₯ Motor overtemp errors traced to thermistor open circuits or improper fan cooling
Why Flexa Systems?
Flexa Systems specializes in repairing and supplying the Parker 690+0007/230/1BS VFD. Whether your drive fails under load, trips with errors, or just wonβt start β weβll get it back online with expert-level diagnostics. We serve all U.S. states from our Texas base with fast turnaround and reliable parts support.
π Important Notes
Please contact us to confirm your exact requirements or verify application compatibility.
Note: Pricing and availability vary depending on unit condition, configuration, and current stock levels.