ALLEN BRADLEY

PowerFlex 753 20F1AND361AN0NNNNN | 361A 300HP 480V VFD

Check availability
Request repair
Field Service Request
Call +1 (254) 254-0005 for a Quote
Delivery
Estimated delivery time for selling products 3-10 days.
Regular repair estimated turnaround time 5-20 days.
Hot rush repair turn around time 1-5 days.

PowerFlex 753 20F1AND361AN0NNNNN | 361A 300HP 480V VFD

Flexa Systems offers expert repair and replacement services for the PowerFlex 753 model 20F1AND361AN0NNNNN.
Based in DFW, Texas, we support manufacturers and industrial facilities across the U.S. with fast turnaround and field-tested support.

Drive Specifications – 20F1AND361AN0NNNNN

  • Series: PowerFlex 753
  • Voltage: 480V AC, 3-phase
  • Output Current: 361 Amps
  • Motor Rating: 300 HP
  • Frame Size: 7
  • Enclosure: NEMA/UL Type Open (IP00/IP20)
  • Input: AC with precharge circuit
  • Braking: No internal resistor or transistor
  • HIM Interface: None (Code 0)

Common PowerFlex 753 Faults We Repair

  • F018 – Motor PTC Trip: Thermal protection triggered by motor temperature sensors
  • F017 – Input Phase Loss: Caused by unbalanced or missing power input legs
  • F014 – Ground Wiring: Improper or floating ground reference within the motor circuit
  • F013 – Ground Fault: Shorted output or insulation breakdown
  • F012 – Hardware Overcurrent: Output short, damaged IGBTs, or bus instability
  • F007 – Motor Overload: Excessive current draw, long acceleration, or improper settings
  • F005 – Motor Overvoltage: Braking resistor failure or regen instability
  • F035 – IPM Overcurrent: Inverter stage protection due to critical surge or fault
  • F064 – Drive Overload: Exceeded drive duty cycle or improper load
  • F152 – No Stop Source: Misconfigured stop logic or missing signal
  • F211 – Safety Board Fault: Internal safety diagnostics failure
  • F906 – Program Error: Firmware or logic configuration problem

All drives are repaired at the component level, tested under load, and backed by our 2-year warranty.

Why Choose Flexa Systems?

  • Based in Texas: We serve the DFW region and ship nationwide
  • In-House Repairs: Board-level diagnostics and rework — not just module swaps
  • In-Stock Replacements: Verified working PowerFlex 753 units available
  • Free Evaluation: No-charge diagnostics with a quote before repair
  • Field Support: On-site services available across Texas
  • Warranty: 2-year coverage on all repairs and exchanges

Need Help with Your 20F1AND361AN0NNNNN Drive?

Whether your VFD shows fault codes or won’t power up, Flexa Systems has the experience to help.

📞 Phone: (254) 254-0005

📧 Email: office@flexa-systems.com

📍 Location: Based in DFW, Texas

Manufacturer

ALLEN BRADLEY

Flexa-Systems LLC is not officially linked as a dealer, agent, or affiliate of any designers, brands, or manufacturers whose products are showcased on www.flexa-systems.com. Any mentioned trademarks, brand names, or logos serve solely for identification purposes and remain the registered trademarks of their respective owners, who maintain their rights. The inclusion of these trademarks, brand names, or products on our website does not imply any affiliation or endorsement by the company, trademark, or brand."

Flexa Systems' (2) Year Limited Warranty

Our Warranty
Flexa Systems LLC offers a comprehensive warranty program to ensure peace of mind for your industrial equipment investments. Limited Warranty Coverage
  • Equipment Repairs:
    We provide a 2-year limited warranty on all industrial equipment repairs performed by our technicians. This warranty demonstrates our commitment to the quality of our workmanship. If a repaired item fails due to a covered defect, we will re-repair it free of charge.
  • New Equipment Sales:
    New equipment carries the original manufacturer's warranty. We will gladly facilitate warranty processes with the manufacturer on your behalf.
  • Refurbished Equipment Sales:
    Refurbished equipment comes with a 2-year limited warranty from Flexa Systems LLC, covering defects in materials and workmanship related to our refurbishment process.
Warranty Exclusions (Applies to both repair and refurbished equipment warranties)
This warranty does not cover:
  • New damage caused by liquid, dust, or object contamination
  • New damage caused by mechanical impact, improper installation, incorrect accessories, voltage or current issues, overloading, or overheating.
  • Severe scratches on the unit
  • Broken display (if applicable)
  • Impact or dropping of the unit
  • Removal or deterioration of the warranty sticker
  • Opening the product's cover (if applicable)
Warranty Claim Process
To initiate a warranty claim, please contact our customer support team. Repair or replacement under warranty can take up to 31 calendar days.
Important Note: We repair industrial equipment from various brands; however, we are not a dealer, agent, or affiliate of any specific designers, brands, or manufacturers.
SKU: 000017043 Categories: ,
Updating…
  • No products in the cart.