If your PowerFlex 700 fails or throws random faults, Flexa Systems can repair your 20BD248F3AYNAED1 in-house at the component level or ship you a fully tested replacement unit from our stocked inventory.
Key Specifications
- Input Voltage: 480V AC
- Current (Amps): 248
- Power Rating: 200 kW / 268 HP
- Frame: 6
- Enclosure: Open/Flange Mount – Front: IP00, NEMA/UL Type Open; Back/Heatsink: IP54, NEMA 12
- HMI Presence: LCD Display, Full Numeric Keypad
- Documentation: Manual
- Brake: Yes
- Internal Braking Resistor: No
- Emission: CE Filter: Yes, CM Choke: Yes
- Comm Slot: EtherNet/IP
- Control & I/O: Vector | 115V AC
- Feedback: Encoder, 12V/5V
Most Common Faults We Can Solve
These are frequent PowerFlex 700 issues. We diagnose quickly and repair at the component level.
- Load Loss: Torque current below [Load Loss Level] for set time.
Fix: Verify mechanical coupling; we check level/time and drive feedback.
- UnderVoltage: DC bus dropped below the minimum threshold.
Fix: Check incoming AC for sags/interruption; we test input and DC bus health and stabilize with line conditioning if needed.
- Cntl Bd Overtemp: Main Control Board over-temperature.
Fix: Check board fan and ambient; we replace fans and re-flow/replace the MCB if required.
- Phase UV/VW/UW Short: Excessive current between output terminals.
Fix: Check for shorted motor/wiring; we repair/replace damaged output stage.
- DB Resistance: Internal DB resistor ohms out of range.
Fix: Replace resistor; we supply/fit correct DB module and test.
- Heatsink OverTemp: Heatsink temperature above limit (or very low).
Fix: Verify ambient, fan operation, and load; we replace fans and clean/recertify cooling path.
- Input Phase Loss: Ripple indicates a missing input phase or blown fuse.
Fix: Inspect fuses and incoming power; we verify phase balance and replace protection if necessary.
Important Notes
Pricing listed on the website is for reference only and is subject to change over time.
Unsure about the exact model? Share a photo or full catalog code. Flexa Systems will confirm compatibility fast.
We service and stock Allen-Bradley PowerFlex 700 VFDs—component-level repairs or ready-to-ship replacements.
- Load testing is performed on all units prior to shipment.
- Lead times and pricing depend on condition and options.
- Expedited exchange programs available.
- 12–24 month coverage on repairs and remans (where applicable).
Repair & Sales • PowerFlex Specialists
Component-level repairs, reman units, and ready-to-ship replacements when available.
Check Availability
Send your requirement — we’ll match repair or stock options.