⚙️ Replacement Parker 690+0100/460/CBS AC Drive | 100 HP | 460V | Flexa Systems Repairs + Stock
Texas-Based Shop & Warehouse — Serving All 50 States with Fast Turnaround 🇺🇸
690+0100/460/CBS | 100 HP | 460V Variable Frequency Drive
This 690+ series AC drive from Parker delivers powerful performance with a 100 HP rating and 460V input configuration. Designed for high-efficiency motor control, this model is configured with a chassis-style enclosure, integrated dynamic brake switch, and fitted system board—ideal for demanding industrial environments.
- Power: 100 HP (Frame F)
- Input Voltage: 380–460V AC ±10%
- Enclosure: Chassis (IP20)
- Braking: Brake power switch installed
- System Board: Installed
🛠️ Most Common Faults We Can Help You With
- Overvoltage: Caused by rapid deceleration or high supply voltages — we’ll repair the circuitry and check the braking chain.
- Undervoltage: Low or missing supply phases, faulty rectifier section — we troubleshoot and resolve it.
- Overcurrent: Detected during acceleration/deceleration or due to shorted windings — our bench test can pinpoint the issue.
- Heatsink Overheat: Poor airflow or faulty fans — we clean, cool, and replace parts as needed.
- Stalled Motor: Motor not turning due to excessive load or wrong configuration — our tuning can fix it.
- Brake Resistor Trip: Happens when stopping heavy loads — we validate resistor sizing and replace failed components.
- Brake Switch Failure: Internal switch damage due to excessive braking cycles — we service or replace.
- Communication Timeout: Short comms timeout settings or board issues — our diagnostics will verify the root cause.
- STO Fault: Safety Torque Off trip — we can repair or replace the STO board reliably.
- Comm Error Code N: Control and power stage communication breakdown — common and fixable in our lab.
- Speed Feedback Error: Error due to encoder or feedback loss — we diagnose encoder and scaling setup.
- Current Limit Trip: Triggers under shock loads — we test motor load response and drive configuration.
- 24V Failure: Output voltage dropped — typically shorted external wiring or internal failure.
- Phase Loss: Missing input phases or blown fuses — our repair includes full supply validation.
- DESAT Trip: Instantaneous current surge — power stage components usually to blame, and we handle them all.
- Ripple DC Voltage: Ripple too high — we check capacitors and missing phase inputs.
- Brake Short Circuit: Excessive braking current — we confirm circuit integrity.
- Overspeed: Drive exceeds setpoint — encoder or feedback tuning needed, which we perform.
- Analog Input Error: Incorrect 4–20mA setup or wiring — we check and reconfigure cleanly.
- Low-Speed Overcurrent: Boosts too high or motor under too much load at low speed — fully tunable.
- Motor Overtemperature: Caused by thermistor faults or overload — we test sensors and settings thoroughly.
🧠 Why Flexa Systems?
Flexa Systems doesn’t just fix VFDs — we revive them. Whether you’re dealing with fault codes, blown drives, or unpredictable behavior, our Texas-based repair shop handles component-level diagnostics and testing to ensure your equipment is production-ready. We also stock select models for faster turnaround — shipping available nationwide.
📌 Important Notes
Please reach out with your specific configuration needs or application details. Flexa Systems both repairs and sells these Parker 690+ drives. Pricing and lead times may vary depending on stock availability and drive condition.