Parker 690+0025/230/1BS | 25 HP (18.5 kW) 230V VFD
- Series: Parker 690+ AC Variable Frequency Drive
- Power Rating: 25 HP (18.5 kW)
- Input Voltage: 230V Β±10%, 50/60Hz
- Enclosure: NEMA 1 (UL Type 1 β general-purpose indoor use)
- Braking Setup: Brake switch fitted (external resistor required)
- System Board: Included
Common Problems We Fix with This Drive π οΈ
- β‘ Overvoltage: usually caused by aggressive deceleration without braking resistor
- π Undervoltage: from unstable input, missing phases, or internal PSU faults
- π¨ Overcurrent: results from improper motor tuning, shorted windings, or sudden torque changes
- π‘οΈ Heatsink trip: blocked airflow, dead fan, or ambient temp exceeding limits
- π Stall faults: too much mechanical load or improperly set stall thresholds
- π₯ Brake resistor overload: frequent decel events or undersized resistor
- π£ Brake switch burnout: happens after continuous high-cycle braking
- π‘ COMMS timeout: from parameter config issues or interference on signal line
- π STO fault: safety board signal issues or failed STO input
- π Internal comm errors: logic board and power section desync, often from firmware failure
- π― Encoder fault: feedback loop out-of-range or bad encoder connection
- β οΈ Current limit exceeded: motor acceleration or torque profile too aggressive
- π 24V supply drop: external short or excessive load
- β οΈ Phase fail: due to input wiring loss or internal trace failure
- π₯ DESAT overcurrent: blown IGBT, faulty gate driver, or heavy load arc fault
- π Ripple voltage issue: common with failing DC bus capacitors or power phase imbalance
- 𧨠Brake fault: resistor path overcurrent or open circuit
- π Overspeed: bad feedback tuning or mechanical instability
- π Analog input issues: sensor wiring or signal calibration mismatch
- π Overcurrent at low speed: boost configured too aggressively or underloaded
- π‘οΈ Motor overtemperature: blocked ventilation, thermistor trip, or mismatched motor
Why Flexa Systems?
Flexa Systems specializes in component-level repair and full replacement for the Parker 690+0025/230/1BS drive. If youβre seeing fault codes, motor stalls, or complete power loss, weβll get it running again. We service clients across the U.S. from our Texas-based repair hub with rapid turnaround and fully tested units in stock.