Parker 690+0010/460/CBS | 10 HP (7.5 kW) 460V VFD

  • Series: 690+ AC Variable Frequency Drive
  • Power Output: 10 HP (7.5 kW)
  • Input Voltage: 460V (Rated 380–460V ±10%)
  • Enclosure: Chassis (IP20) — optimized for panel mounting and cabinet installations
  • Braking Setup: Equipped with brake switch, external resistor not included
  • System Board: Included

Repairs for Faults We Commonly Handle 🛠️

  • 🔋 DC overvoltage — often tied to braking misconfigurations or excessive regenerative energy
  • ⚡ Undervoltage events from unstable input power, phase drops, or internal PSU damage
  • 🚨 Motor overcurrent from improper boost levels, miswired outputs, or shorted windings
  • 🌡️ Thermal issues on heatsink from clogged airflow, tight enclosures, or faulty fan modules
  • ⛔ Stall trips due to low torque limit, mechanical overload, or misaligned config
  • 🔥 Brake resistor overload during rapid stops, especially without delay tuning
  • 💥 Brake switch tripping from constant heavy deceleration cycles
  • 📡 Communication faults triggered by cable faults, improper setup, or damaged ports
  • 🛑 STO safety issues tied to failed Safe Torque Off circuitry
  • 🔁 Power/control board communication breakdown, often firmware or bus-related
  • 🎯 Speed feedback issues — feedback loop instability or encoder malfunctions
  • ⚠️ Current limit exceeded during acceleration or sudden torque surges
  • 🔌 24V control output loss — likely from overcurrent or shorted terminal loads
  • ⚠️ Input phase detection faults, may stem from fuse failure or bad terminal connections
  • 💣 DESAT trip conditions caused by IGBT faults or power board issues
  • 🔄 High ripple voltage across DC bus — indicates capacitor or input phase irregularities
  • 🧨 Brake circuit shorted or overcurrent detected — typically resistor or wiring related
  • 🚀 Overspeed detection linked to encoder errors or mechanical instability
  • 📏 Analog input configuration errors — signal overrange or sensor wiring fault
  • 🐌 Low-speed overcurrent, often from incorrect boost settings or motor tuning
  • 🌡️ Motor thermal trip from poor ventilation, continuous low-speed use, or thermistor failure

Why Partner with Flexa Systems?

Flexa Systems offers expert-level repair and supply solutions for Parker drives like the 690+0010/460/CBS. Whether you’re battling feedback failures, drive trips, or startup issues — we’ve seen it, solved it, and shipped it. Based in Texas, serving all 50 states with reliable, fast turnaround.

📌 Important Notes

Please contact us to confirm your exact requirements or verify application compatibility.

Note: Pricing and availability vary depending on unit condition, configuration, and current stock levels.

Flexa-Systems LLC is not officially linked as a dealer, agent, or affiliate of any designers, brands, or manufacturers whose products are showcased on www.flexa-systems.com. Any mentioned trademarks, brand names, or logos serve solely for identification purposes and remain the registered trademarks of their respective owners, who maintain their rights. The inclusion of these trademarks, brand names, or products on our website does not imply any affiliation or endorsement by the company, trademark, or brand."

Flexa Systems' (2) Year Limited Warranty

Our Warranty
Flexa Systems LLC offers a comprehensive warranty program to ensure peace of mind for your industrial equipment investments. Limited Warranty Coverage
  • Equipment Repairs:
    We provide a 2-year limited warranty on all industrial equipment repairs performed by our technicians. This warranty demonstrates our commitment to the quality of our workmanship. If a repaired item fails due to a covered defect, we will re-repair it free of charge.
  • New Equipment Sales:
    New equipment carries the original manufacturer's warranty. We will gladly facilitate warranty processes with the manufacturer on your behalf.
  • Refurbished Equipment Sales:
    Refurbished equipment comes with a 2-year limited warranty from Flexa Systems LLC, covering defects in materials and workmanship related to our refurbishment process.
Warranty Exclusions (Applies to both repair and refurbished equipment warranties)
This warranty does not cover:
  • New damage caused by liquid, dust, or object contamination
  • New damage caused by mechanical impact, improper installation, incorrect accessories, voltage or current issues, overloading, or overheating.
  • Severe scratches on the unit
  • Broken display (if applicable)
  • Impact or dropping of the unit
  • Removal or deterioration of the warranty sticker
  • Opening the product's cover (if applicable)
Warranty Claim Process
To initiate a warranty claim, please contact our customer support team. Repair or replacement under warranty can take up to 31 calendar days.
Important Note: We repair industrial equipment from various brands; however, we are not a dealer, agent, or affiliate of any specific designers, brands, or manufacturers.
SKU: 32016 Categories: ,
Updating…
  • No products in the cart.