Technical Specifications – 22B-B017N104BD

  • Series: PowerFlex 40
  • Catalog Number: 22B-B017N104BD
  • Voltage: 480V AC, 3-Phase
  • Output Current: 17.5 Amps
  • Motor Power: 10 HP (7.5 kW)
  • EMI Filter: None (Suffix N)
  • Enclosure: IP20 / NEMA Type 1 Open Type
  • Interface Module: Removable HIM (BD suffix)
  • Applications: Industrial motors, fans, conveyors, pumps, material handling systems

PowerFlex 40 Common Faults – We Repair Them All

  • F081 – Auto Restart Tries Exceeded: Often indicates persistent trip conditions. We identify and resolve underlying issues such as load imbalance, parameter misconfiguration, or control signal instability.
  • F111 – Power Loss: Triggered by voltage dropouts or power supply failure. We test and repair the input rectifier, DC bus, and supply stages.
  • F004 – UnderVoltage: Caused by weak power input or internal capacitor degradation. We test the power chain and replace faulty components.
  • F013 – Ground Fault: A safety-triggered shutdown due to output leakage. We isolate and repair motor side faults, damaged IGBTs, or insulation failure.
  • F012 – Hardware Overcurrent: Indicates a hard short or drive-stage failure. We diagnose the output bridge, replace damaged transistors, and test full load operation.
  • F005 – OverVoltage: Often from short deceleration times or regen issues. We test braking components and reconfigure control logic.
  • F006 – Motor Stall: Triggered by mechanical jams or improper ramp settings. We test the load interface and reset parameters.
  • F008 – Heatsink Over Temperature: Usually due to cooling issues or dust buildup. We clean the drive, replace fans, and ensure stable thermal behavior.

We handle these issues in-house at our DFW-based repair center — fast, cost-effective, and backed by full testing and warranty.

Repair or Replace – We’ve Got the Drive You Need

  • Located in Lewisville, Texas: Serving the DFW metro area and nationwide industrial clients.
  • In-Stock Replacements: We stock tested and verified 22B-B017N104BD drives, ready to ship same-day in many cases.
  • Component-Level Repair: We repair down to board and chip level, saving time and cost versus OEM service.
  • Fast Turnaround: Standard and expedited repair options available.
  • 2-Year Warranty: Included on all repairs and replacements.
  • No-Fix, No-Fee: If we can’t fix it, you don’t pay.

Need Help with Your 22B-B017N104BD Drive?

Contact Flexa Systems today to request a quote, book a repair, or confirm availability of a replacement drive.

📞 Phone: (254) 254-0005

📧 Email: office@flexa-systems.com

📍 Location: Flexa Systems – Lewisville, DFW, Texas

Manufacturer

ALLEN BRADLEY

Flexa-Systems LLC is not officially linked as a dealer, agent, or affiliate of any designers, brands, or manufacturers whose products are showcased on www.flexa-systems.com. Any mentioned trademarks, brand names, or logos serve solely for identification purposes and remain the registered trademarks of their respective owners, who maintain their rights. The inclusion of these trademarks, brand names, or products on our website does not imply any affiliation or endorsement by the company, trademark, or brand."

Flexa Systems' (2) Year Limited Warranty

Our Warranty
Flexa Systems LLC offers a comprehensive warranty program to ensure peace of mind for your industrial equipment investments. Limited Warranty Coverage
  • Equipment Repairs:
    We provide a 2-year limited warranty on all industrial equipment repairs performed by our technicians. This warranty demonstrates our commitment to the quality of our workmanship. If a repaired item fails due to a covered defect, we will re-repair it free of charge.
  • New Equipment Sales:
    New equipment carries the original manufacturer's warranty. We will gladly facilitate warranty processes with the manufacturer on your behalf.
  • Refurbished Equipment Sales:
    Refurbished equipment comes with a 2-year limited warranty from Flexa Systems LLC, covering defects in materials and workmanship related to our refurbishment process.
Warranty Exclusions (Applies to both repair and refurbished equipment warranties)
This warranty does not cover:
  • New damage caused by liquid, dust, or object contamination
  • New damage caused by mechanical impact, improper installation, incorrect accessories, voltage or current issues, overloading, or overheating.
  • Severe scratches on the unit
  • Broken display (if applicable)
  • Impact or dropping of the unit
  • Removal or deterioration of the warranty sticker
  • Opening the product's cover (if applicable)
Warranty Claim Process
To initiate a warranty claim, please contact our customer support team. Repair or replacement under warranty can take up to 31 calendar days.
Important Note: We repair industrial equipment from various brands; however, we are not a dealer, agent, or affiliate of any specific designers, brands, or manufacturers.
SKU: 000000862 Categories: ,
Updating…
  • No products in the cart.