📦 Shipping from Texas Warehouse
Serving All 50 States | Based in Texas | Units In-Stock & Ready for Fast Turnaround
Parker 690+0025/230/1BS | 25 HP (18.5 kW) 230V VFD
- Series: Parker 690+ AC Variable Frequency Drive
- Power Rating: 25 HP (18.5 kW)
- Input Voltage: 230V ±10%, 50/60Hz
- Enclosure: NEMA 1 (UL Type 1 – general-purpose indoor use)
- Braking Setup: Brake switch fitted (external resistor required)
- System Board: Included
Common Problems We Fix with This Drive 🛠️
- ⚡ Overvoltage: usually caused by aggressive deceleration without braking resistor
- 🔋 Undervoltage: from unstable input, missing phases, or internal PSU faults
- 🚨 Overcurrent: results from improper motor tuning, shorted windings, or sudden torque changes
- 🌡️ Heatsink trip: blocked airflow, dead fan, or ambient temp exceeding limits
- 🛑 Stall faults: too much mechanical load or improperly set stall thresholds
- 🔥 Brake resistor overload: frequent decel events or undersized resistor
- 💣 Brake switch burnout: happens after continuous high-cycle braking
- 📡 COMMS timeout: from parameter config issues or interference on signal line
- 🛑 STO fault: safety board signal issues or failed STO input
- 🔁 Internal comm errors: logic board and power section desync, often from firmware failure
- 🎯 Encoder fault: feedback loop out-of-range or bad encoder connection
- ⚠️ Current limit exceeded: motor acceleration or torque profile too aggressive
- 🔌 24V supply drop: external short or excessive load
- ⚠️ Phase fail: due to input wiring loss or internal trace failure
- 💥 DESAT overcurrent: blown IGBT, faulty gate driver, or heavy load arc fault
- 🔄 Ripple voltage issue: common with failing DC bus capacitors or power phase imbalance
- 🧨 Brake fault: resistor path overcurrent or open circuit
- 🚀 Overspeed: bad feedback tuning or mechanical instability
- 📏 Analog input issues: sensor wiring or signal calibration mismatch
- 🐌 Overcurrent at low speed: boost configured too aggressively or underloaded
- 🌡️ Motor overtemperature: blocked ventilation, thermistor trip, or mismatched motor
Why Flexa Systems?
Flexa Systems specializes in component-level repair and full replacement for the Parker 690+0025/230/1BS drive. If you’re seeing fault codes, motor stalls, or complete power loss, we’ll get it running again. We service clients across the U.S. from our Texas-based repair hub with rapid turnaround and fully tested units in stock.
📌 Important Notes
Please contact us to confirm your exact requirements or verify application compatibility.
Note: Pricing and availability vary depending on unit condition, configuration, and current stock levels.