📦 Shipping from Texas Warehouse
Serving All 50 States | Based in Texas | Units In-Stock & Ready for Fast Turnaround
Parker 690+0010/460/CBS | 10 HP (7.5 kW) 460V VFD
- Series: 690+ AC Variable Frequency Drive
- Power Output: 10 HP (7.5 kW)
- Input Voltage: 460V (Rated 380–460V ±10%)
- Enclosure: Chassis (IP20) — optimized for panel mounting and cabinet installations
- Braking Setup: Equipped with brake switch, external resistor not included
- System Board: Included
Repairs for Faults We Commonly Handle 🛠️
- 🔋 DC overvoltage — often tied to braking misconfigurations or excessive regenerative energy
- ⚡ Undervoltage events from unstable input power, phase drops, or internal PSU damage
- 🚨 Motor overcurrent from improper boost levels, miswired outputs, or shorted windings
- 🌡️ Thermal issues on heatsink from clogged airflow, tight enclosures, or faulty fan modules
- ⛔ Stall trips due to low torque limit, mechanical overload, or misaligned config
- 🔥 Brake resistor overload during rapid stops, especially without delay tuning
- 💥 Brake switch tripping from constant heavy deceleration cycles
- 📡 Communication faults triggered by cable faults, improper setup, or damaged ports
- 🛑 STO safety issues tied to failed Safe Torque Off circuitry
- 🔁 Power/control board communication breakdown, often firmware or bus-related
- 🎯 Speed feedback issues — feedback loop instability or encoder malfunctions
- ⚠️ Current limit exceeded during acceleration or sudden torque surges
- 🔌 24V control output loss — likely from overcurrent or shorted terminal loads
- ⚠️ Input phase detection faults, may stem from fuse failure or bad terminal connections
- 💣 DESAT trip conditions caused by IGBT faults or power board issues
- 🔄 High ripple voltage across DC bus — indicates capacitor or input phase irregularities
- 🧨 Brake circuit shorted or overcurrent detected — typically resistor or wiring related
- 🚀 Overspeed detection linked to encoder errors or mechanical instability
- 📏 Analog input configuration errors — signal overrange or sensor wiring fault
- 🐌 Low-speed overcurrent, often from incorrect boost settings or motor tuning
- 🌡️ Motor thermal trip from poor ventilation, continuous low-speed use, or thermistor failure
Why Partner with Flexa Systems?
Flexa Systems offers expert-level repair and supply solutions for Parker drives like the 690+0010/460/CBS. Whether you’re battling feedback failures, drive trips, or startup issues — we’ve seen it, solved it, and shipped it. Based in Texas, serving all 50 states with reliable, fast turnaround.
📌 Important Notes
Please contact us to confirm your exact requirements or verify application compatibility.
Note: Pricing and availability vary depending on unit condition, configuration, and current stock levels.