📦 Shipping from Texas Warehouse
Serving All 50 States | Based in Texas | Units In-Stock & Ready for Fast Turnaround
Parker 690+0007/230/1BS | 7.5 HP (5.5 kW) 230V VFD
- Series: 690+ AC Variable Frequency Drive
- Power Output: 7.5 HP (5.5 kW)
- Input Voltage: 230V ±10%, 50/60Hz
- Enclosure: NEMA 1 (UL Type 1) for standard indoor environments
- Brake Setup: Integrated brake switch (resistor must be ordered separately)
- System Board: Supplied with system control board
Common Faults We Can Professionally Repair 🔍
- 📈 Overvoltage during braking or regen cycles — likely due to resistor circuit issues or config mismatch
- 🔋 Undervoltage from phase loss, poor incoming power, or defective drive components
- 🚨 Overcurrent tripping caused by improper motor setup, shorts, or aggressive acceleration
- 🌡️ Heatsink over-temp alarms resulting from poor panel airflow or fan failure
- 🛑 Stall detection triggering due to incorrect boost settings or excessive mechanical load
- 🔥 Brake resistor thermal overload from frequent high-torque stopping
- 💥 Brake switch component degradation due to inertia loads or under-configured decel profiles
- 📶 Comms timeout from incorrectly set parameters or broken signal wiring
- 🧯 STO safety trip — this can indicate a faulty STO module or connection
- ⚡ Internal comms failure between boards — often fixed with firmware or logic board repairs
- 🚀 Speed feedback errors over tolerance — typical in encoder misalignment or sensor issues
- 🔌 Current limit trips from unexpected torque spikes or load fluctuation
- 💡 24V control circuit drops due to shorts or overdraw in the external system
- ⚠️ Phase fail detection from open fuses or miswiring — or internal drive PCB faults
- ⚡ DESAT fault indicating power transistor or IGBT trouble — common in high-torque applications
- 🔋 VDC ripple trips — caused by missing input phases or aged DC link capacitors
- 🛠️ Brake circuit current trips (short or overload) traced to wiring or resistor failure
- 📉 Overspeed trips triggered by feedback instability or faulty speed control circuits
- 📏 Analog input misreadings due to wiring damage or signal mode conflicts
- 🐌 Excess current at low speed due to overly aggressive boost or drive config
- 🔥 Motor overtemp errors traced to thermistor open circuits or improper fan cooling
Why Flexa Systems?
Flexa Systems specializes in repairing and supplying the Parker 690+0007/230/1BS VFD. Whether your drive fails under load, trips with errors, or just won’t start — we’ll get it back online with expert-level diagnostics. We serve all U.S. states from our Texas base with fast turnaround and reliable parts support.
📌 Important Notes
Please contact us to confirm your exact requirements or verify application compatibility.
Note: Pricing and availability vary depending on unit condition, configuration, and current stock levels.