Factory-Trained Technicians
ISO-compliant process
Allen-Bradley PowerFlex 700 20BD2P1A3AYNACD1 | 1 kW / 2.1 A VFD
Expert Repair or Tested Spare on the Shelf
If your PowerFlex 700 fails or throws random faults, Flexa Systems can repair your 20BD2P1A3AYNACD1 in-house at the component level or ship you a fully tested replacement unit from our stocked inventory.
Key Specifications
- Input Voltage: 480V AC
- Current (Amps): 2.1
- Power Rating: 1 kW / 1 HP
- Frame: 0
- Enclosure: IP20, NEMA/UL Type 1
- HMI Presence: LCD Display, Full Numeric Keypad
- Documentation: Manual
- Brake: Yes
- Internal Braking Resistor: No
- Emission: CE Filter: Yes, CM Choke: Yes
- Comm Slot: ControlNet (Coax)
- Control & I/O: Vector | 115V AC
- Feedback: Encoder, 12V/5V
Most Common Faults We Can Solve
These are frequent PowerFlex 700 issues. We diagnose quickly and repair at the component level.
- Motor Overload: Internal electronic overload trip.
Fix: Lower load below Motor FLA; we confirm FLA programming and motor sizing.
- Heatsink OverTemp: Heatsink temperature above limit (or very low).
Fix: Verify ambient, fan operation, and load; we replace fans and clean/recertify cooling path.
- Output Phase Loss: Current lost in one/more output phases.
Fix: Check motor/drive wiring; we test phase continuity and repair output stage/wiring faults.
- UnderVoltage: DC bus dropped below the minimum threshold.
Fix: Check incoming AC for sags/interruption; we test input and DC bus health and stabilize with line conditioning if needed.
- OverVoltage: DC bus voltage exceeded the maximum value.
Fix: Verify line transients; extend decel time or add a dynamic brake option; we can size/install a DB kit and soak-test the drive.
- Load Loss: Torque current below [Load Loss Level] for set time.
Fix: Verify mechanical coupling; we check level/time and drive feedback.
- Ground Fault: >25% rating current to earth ground detected.
Fix: Meg-check motor and cable for ground; we isolate insulation faults and re-terminate.
Important Notes
Pricing listed on the website is for reference only and is subject to change over time.
Send us your full catalog number (or a photo) and Flexa Systems will verify compatibility before you order.
We keep you running with repair or replacement for Allen-Bradley PowerFlex 700 drives—whichever gets you back online faster.
- Units are inspected, repaired as needed, and load-tested.
- Lead time and pricing depend on condition and availability.
- Exchange and hot-rush options offered on request.
- 12–24 month warranty for repairs/remans where applicable.
Repair & Sales • PowerFlex Specialists
Component-level repairs, reman units, and ready-to-ship replacements when available.
Check Availability
Send your requirement — we’ll match repair or stock options.