Parker 690+0015/460/1BS | 15 HP (11 kW) 460V VFD
- Series: 690+ AC Variable Frequency Drive
- Power Rating: 15 HP (11 kW)
- Voltage Input: 460V (Nominal range 380–460V ±10%)
- Enclosure: NEMA 1 — Standard indoor cabinet-ready design
- Braking Setup: Braking power switch included; external resistor required
- System Board: Included
Frequent Issues Flexa Systems Can Resolve ⚙️
- ⚡ Drive overvoltage due to improper deceleration, regen energy buildup, or failed braking path
- 🔋 Undervoltage conditions from missing input phase or power brownout
- 🚨 Drive tripping on overcurrent caused by shorted motors, incorrect motor parameters, or rapid ramp-up
- 🌡️ Heatsink temp faults from blocked airflow, failing fans, or ambient overheating
- ⛔ Motor stall detection due to heavy mechanical load or under-tuned torque limit
- 🔥 Brake resistor overload during high-speed decel without sufficient braking delay
- 💥 Brake switch damage under frequent duty or incorrect resistor sizing
- 📡 COMMS loss from noisy wiring, incorrect timeout settings, or damaged ports
- 🛑 STO-related faults — commonly resolved by STO board or harness replacement
- 🔄 Internal controller to IGBT gate board communication errors
- 🎯 Speed feedback fault — encoder instability or signal dropout
- ⚠️ Current limit faults triggered by motor shock load or acceleration misconfiguration
- 🔌 24V output undervoltage caused by shorts in control wiring or external relay overloads
- ⚠️ Phase failure from fuse faults, broken terminals, or PCB traces
- 💣 DESAT trip conditions from faulty IGBTs or control timing errors
- 🔁 Ripple alarms from degraded DC capacitors or poor supply balance
- 🧨 Brake overcurrent conditions from wiring mistakes or mismatched resistors
- 🚀 Overspeed errors from encoder noise or unstable feedback tuning
- 📏 Analog signal range issues — wiring or misconfigured input mode
- 🐌 High current draw at low speed, typically caused by excessive boost or torque misalignment
- 🌡️ Motor overheating from improper cooling, thermistor breakage, or incorrect motor selection
Why Choose Flexa Systems?
Flexa Systems repairs and stocks the Parker 690+0015/460/1BS — ensuring minimal downtime for your operations. Whether your unit suffers from startup issues, drive trips, or feedback faults, we offer reliable diagnostics and fast turnaround from our Texas-based warehouse, with service available across all 50 states.
📌 Important Notes
Please contact us to confirm your exact requirements or verify application compatibility.
Note: Pricing and availability vary depending on unit condition, configuration, and current stock levels.