Rush Service Available
Same-day evaluation
Allen-Bradley PowerFlex 700 20BB6P8A3AYYBEB0 | 2 kW / 6.8 A VFD
Get it Repaired or Get a Replacement Today
If your PowerFlex 700 fails or throws random faults, Flexa Systems can repair your 20BB6P8A3AYYBEB0 in-house at the component level or ship you a fully tested replacement unit from our stocked inventory.
Key Specifications
- Input Voltage: 240V AC
- Current (Amps): 6.8
- Power Rating: 2 kW / 3 HP
- Frame: 1
- Enclosure: IP20, NEMA/UL Type 1
- HMI Presence: LCD Display, Full Numeric Keypad
- Documentation: Manual
- Brake: Yes
- Internal Braking Resistor: Yes
- Emission: CE Filter: Yes, CM Choke: No
- Comm Slot: EtherNet/IP
- Control & I/O: Standard | 115V AC
- Feedback: None
Most Common Faults We Can Solve
These are frequent PowerFlex 700 issues. We diagnose quickly and repair at the component level.
- Output Phase Loss: Current lost in one/more output phases.
Fix: Check motor/drive wiring; we test phase continuity and repair output stage/wiring faults.
- SW OverCurrent: 1 ms current exceeded its rating (above cont., below HW limit).
Fix: Reduce load/boost/brake volts; we capture waveforms and reset to safe values.
- UnderVoltage: DC bus dropped below the minimum threshold.
Fix: Check incoming AC for sags/interruption; we test input and DC bus health and stabilize with line conditioning if needed.
- Input Phase Loss: Ripple indicates a missing input phase or blown fuse.
Fix: Inspect fuses and incoming power; we verify phase balance and replace protection if necessary.
- Ground Fault: >25% rating current to earth ground detected.
Fix: Meg-check motor and cable for ground; we isolate insulation faults and re-terminate.
- OverVoltage: DC bus voltage exceeded the maximum value.
Fix: Verify line transients; extend decel time or add a dynamic brake option; we can size/install a DB kit and soak-test the drive.
- Load Loss: Torque current below [Load Loss Level] for set time.
Fix: Verify mechanical coupling; we check level/time and drive feedback.
Important Notes
Pricing listed on the website is for reference only and is subject to change over time.
Send us your full catalog number (or a photo) and Flexa Systems will verify compatibility before you order.
We keep you running with repair or replacement for Allen-Bradley PowerFlex 700 drives—whichever gets you back online faster.
- Units are inspected, repaired as needed, and load-tested.
- Lead time and pricing depend on condition and availability.
- Exchange and hot-rush options offered on request.
- 12–24 month warranty for repairs/remans where applicable.