Fast Turnaround & Testing
Phone support by engineers
Allen-Bradley PowerFlex 700 20BD014A3AYYARC1 | 10 kW / 14 A VFD
Bench Repair or Advanced Exchange Program
If your PowerFlex 700 fails or throws random faults, Flexa Systems can repair your 20BD014A3AYYARC1 in-house at the component level or ship you a fully tested replacement unit from our stocked inventory.
Key Specifications
- Input Voltage: 480V AC
- Current (Amps): 14
- Power Rating: 10 kW / 13 HP
- Frame: 1
- Enclosure: IP20, NEMA/UL Type 1
- HMI Presence: LCD Display, Full Numeric Keypad
- Documentation: Manual
- Brake: Yes
- Internal Braking Resistor: Yes
- Emission: CE Filter: Yes, CM Choke: Yes
- Comm Slot: N/A
- Control & I/O: Vector | 24V DC
- Feedback: Encoder, 12V/5V
Most Common Faults We Can Solve
These are frequent PowerFlex 700 issues. We diagnose quickly and repair at the component level.
- UnderVoltage: DC bus dropped below the minimum threshold.
Fix: Check incoming AC for sags/interruption; we test input and DC bus health and stabilize with line conditioning if needed.
- Motor Overload: Internal electronic overload trip.
Fix: Lower load below Motor FLA; we confirm FLA programming and motor sizing.
- OverVoltage: DC bus voltage exceeded the maximum value.
Fix: Verify line transients; extend decel time or add a dynamic brake option; we can size/install a DB kit and soak-test the drive.
- Input Phase Loss: Ripple indicates a missing input phase or blown fuse.
Fix: Inspect fuses and incoming power; we verify phase balance and replace protection if necessary.
- Load Loss: Torque current below [Load Loss Level] for set time.
Fix: Verify mechanical coupling; we check level/time and drive feedback.
- Decel Inhibit: Bus regulation halts decel to limit DC bus.
Fix: Verify line & grounding, add DB resistor or lengthen decel; we configure/supply DB.
- Heatsink OverTemp: Heatsink temperature above limit (or very low).
Fix: Verify ambient, fan operation, and load; we replace fans and clean/recertify cooling path.
Important Notes
Pricing listed on the website is for reference only and is subject to change over time.
Send us your full catalog number (or a photo) and Flexa Systems will verify compatibility before you order.
We keep you running with repair or replacement for Allen-Bradley PowerFlex 700 drives—whichever gets you back online faster.
- Units are inspected, repaired as needed, and load-tested.
- Lead time and pricing depend on condition and availability.
- Exchange and hot-rush options offered on request.
- 12–24 month warranty for repairs/remans where applicable.
Free Evaluation • No Fix, No Fee
Component-level repairs and stocked units. Fast help from our Dallas–Fort Worth team — we ship nationwide.
Get Help Now
Describe the fault or attach a photo — we’ll advise the quickest path.