{"product_id":"allen-bradley-1336t-b040-aa-gm1-gt2en-ha2","title":"Allen-Bradley 1336T-B040-AA-GM1-GT2EN-HA2","description":"\u003cstyle\u003e\n.flexa-desc { font-family:-apple-system,BlinkMacSystemFont,'Segoe UI',sans-serif; color:#1f2937; line-height:1.7; }\n.flexa-desc .desc-intro { font-size:15px; color:#374151; margin-bottom:0; }\n.flexa-desc .desc-section { margin-top:28px; }\n.flexa-desc .desc-section-title { font-size:15px; font-weight:700; color:#111827; text-transform:uppercase; letter-spacing:.05em; padding-bottom:10px; border-bottom:2px solid #e5e7eb; margin-bottom:16px; }\n.flexa-desc .desc-service-grid { display:grid; grid-template-columns:repeat(3,1fr); gap:12px; }\n.flexa-desc .desc-service-card { border-radius:10px; padding:16px; border:1px solid #e5e7eb; }\n.flexa-desc .desc-service-repair { background:#fff7ed; border-color:#fed7aa; }\n.flexa-desc .desc-service-ref { background:#f0fdf4; border-color:#bbf7d0; }\n.flexa-desc .desc-service-new { background:#eff6ff; border-color:#bfdbfe; }\n.flexa-desc .desc-service-label { font-weight:700; font-size:13px; text-transform:uppercase; letter-spacing:.04em; margin-bottom:8px; }\n.flexa-desc .desc-service-repair .desc-service-label { color:#c2410c; }\n.flexa-desc .desc-service-ref .desc-service-label { color:#15803d; }\n.flexa-desc .desc-service-new .desc-service-label { color:#1d4ed8; }\n.flexa-desc .desc-service-body { font-size:13px; color:#4b5563; line-height:1.6; }\n.flexa-desc .desc-faq-item { margin-bottom:16px; padding:14px 16px; background:#f9fafb; border-radius:8px; border-left:3px solid #e5e7eb; }\n.flexa-desc .desc-faq-item:last-child { margin-bottom:0; }\n.flexa-desc .desc-faq-q { font-weight:700; font-size:14px; color:#111827; margin-bottom:6px; }\n.flexa-desc .desc-faq-a { font-size:13px; color:#4b5563; line-height:1.6; }\n.flexa-desc .desc-seo { margin-top:24px; padding:14px 16px; background:#f3f4f6; border-radius:8px; font-size:13px; color:#6b7280; line-height:1.6; }\n@media(max-width:640px){ .flexa-desc .desc-service-grid { grid-template-columns:1fr; } }\n\u003c\/style\u003e\n\u003cdiv class=\"flexa-desc\"\u003e\n  \u003cp class=\"desc-intro\"\u003e1336T-B040-AA-GM1-GT2EN-HA2 repair service is available through Flexa Systems for this discontinued Allen Bradley variable frequency drive, and our team handles ALLEN BRADLEY 1336T-B040-AA-GM1-GT2EN-HA2 repair along with 1336T-B040-AA-GM1-GT2EN-HA2 refurbished unit sales for facilities that need an immediate solution. This unit is a 40HP, 480 VAC three-phase drive belonging to Allen Bradley's 1336 PLUS II T-series platform, engineered for precise AC motor speed control in demanding process environments. Facilities searching for 1336T-B040-AA-GM1-GT2EN-HA2 troubleshooting support will find that this drive's GM1 option denotes a remote mount keypad configuration, while the GT2EN suffix indicates an embedded EtherNet\/IP communication adapter — critical details when diagnosing network-related faults. The HA2 option adds a main AC input disconnect, making this a self-contained drive assembly commonly found in packaging lines, HVAC systems, pump stations, and material handling conveyors. If you've been searching for 1336T-B040-AA-GM1-GT2EN-HA2 repair near me, Flexa Systems ships repaired units nationwide from our facility in Lewisville, TX with fast turnaround. Our industrial VFD repair process includes free diagnostics on every incoming unit, component-level inspection of the IGBT power stage, gate driver boards, and DC bus capacitors. Because Allen Bradley officially discontinued this model, sourcing a verified 1336T-B040-AA-GM1-GT2EN-HA2 replacement or having your existing unit repaired by a specialist is the most cost-effective path to restoring production uptime.\u003c\/p\u003e\n\u003cdiv class=\"desc-section\"\u003e\n  \u003cdiv class=\"desc-section-title\"\u003eTechnical Specifications\u003c\/div\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;border-radius:8px;overflow:hidden;border:1px solid #e5e7eb;\"\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;color:#374151;width:38%;font-size:13px;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;color:#1f2937;font-size:13px;\"\u003e1336T-B040-AA-GM1-GT2EN-HA2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;color:#374151;width:38%;font-size:13px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;color:#1f2937;font-size:13px;\"\u003eALLEN BRADLEY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;color:#374151;width:38%;font-size:13px;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;color:#1f2937;font-size:13px;\"\u003e480 VAC 3 Phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;color:#374151;width:38%;font-size:13px;\"\u003ePower Rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;color:#1f2937;font-size:13px;\"\u003e40HP\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"desc-section\"\u003e\n  \u003cdiv class=\"desc-section-title\"\u003eCompatibility\u003c\/div\u003e\n  \u003cp style=\"font-size:14px;color:#374151;margin:0;line-height:1.7;\"\u003eThe 1336T-B040-AA-GM1-GT2EN-HA2 compatible with Allen Bradley's ControlLogix (1756 series) and CompactLogix (1769 series) PLC platforms via its embedded EtherNet\/IP adapter, allowing full parameter configuration and status monitoring through RSLogix 5000 or Studio 5000 Logix Designer software. ALLEN BRADLEY 1336T-B040-AA-GM1-GT2EN-HA2 integration is also supported with legacy SLC 500 and MicroLogix controllers using the 1336-GM6 remote I\/O adapter option, and the drive accepts standard analog (0–10V, 4–20mA) and digital I\/O control signals compatible with most PLC output modules. This drive is rated for NEMA frame motors up to 40HP at 460V and is compatible with Allen Bradley's 1321-3R series line reactors, 1321-RWR series dynamic braking resistors, and 1336-BRF series bypass panels for critical load applications. As a 1336T-B040-AA-GM1-GT2EN-HA2 replacement for earlier 1336 PLUS (catalog prefix 1336F) drives or the 1336 IMPACT series, the wiring footprint and conduit entry points are similar enough to simplify retrofit installations in existing enclosures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"desc-section\"\u003e\n  \u003cdiv class=\"desc-section-title\"\u003eService Options\u003c\/div\u003e\n  \u003cdiv class=\"desc-service-grid\"\u003e\n    \u003cdiv class=\"desc-service-card desc-service-repair\"\u003e\n      \u003cdiv class=\"desc-service-label\"\u003eRepair Service\u003c\/div\u003e\n      \u003cdiv class=\"desc-service-body\"\u003eShip your faulty 1336T-B040-AA-GM1-GT2EN-HA2 to our facility. Our certified technicians perform IGBT testing, capacitor inspection, gate driver diagnostics, and full load testing. Typical turnaround: 5–7 business days. 2-year warranty included.\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"desc-service-card desc-service-ref\"\u003e\n      \u003cdiv class=\"desc-service-label\"\u003eRefurbished\u003c\/div\u003e\n      \u003cdiv class=\"desc-service-body\"\u003eIn-stock ALLEN BRADLEY 1336T-B040-AA-GM1-GT2EN-HA2 variable frequency drive, reconditioned to OEM specifications and verified under load. Ships immediately. 2-year warranty included.\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"desc-service-card desc-service-new\"\u003e\n      \u003cdiv class=\"desc-service-label\"\u003eBrand New\u003c\/div\u003e\n      \u003cdiv class=\"desc-service-body\"\u003eNew 1336T-B040-AA-GM1-GT2EN-HA2 in original ALLEN BRADLEY packaging. Full manufacturer warranty applies. Contact us to confirm availability and lead time.\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"desc-section\"\u003e\n  \u003cdiv class=\"desc-section-title\"\u003eCommon Failure Modes\u003c\/div\u003e\n  \u003cul style=\"margin:0;padding-left:20px;line-height:1.7;\"\u003e\n\u003cli style=\"padding:5px 0;color:#374151;font-size:14px;\"\u003eDC bus overvoltage fault (F009) triggered during deceleration ramps in 1336T-B040-AA-GM1-GT2EN-HA2 units where dynamic braking resistors are undersized or the braking IGBT has failed open — common in applications with high-inertia loads like centrifuges or large fans.\u003c\/li\u003e\n\u003cli style=\"padding:5px 0;color:#374151;font-size:14px;\"\u003eGate driver board failure causing an output phase loss fault (F012) and asymmetrical output voltage, a frequent finding during 1336T-B040-AA-GM1-GT2EN-HA2 troubleshooting on units that have operated in high-ambient-temperature enclosures above 40°C without adequate airflow.\u003c\/li\u003e\n\u003cli style=\"padding:5px 0;color:#374151;font-size:14px;\"\u003eElectrolytic DC bus capacitor degradation resulting in low bus voltage faults (F004) and erratic drive behavior under load — capacitors in this vintage of 1336T-B040-AA-GM1-GT2EN-HA2 units are typically past service life after 10–15 years and show measurable ESR increase before catastrophic failure.\u003c\/li\u003e\n\u003cli style=\"padding:5px 0;color:#374151;font-size:14px;\"\u003eEtherNet\/IP communication loss faults (E-NET ERR) caused by corrupted firmware on the embedded GT2EN communication adapter after a power surge or improper drive parameter reset, requiring adapter reinitialization or board-level repair to restore network connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"desc-section\"\u003e\n  \u003cdiv class=\"desc-section-title\"\u003eFrequently Asked Questions\u003c\/div\u003e\n  \u003cdiv class=\"desc-faq-item\"\u003e\n\u003cdiv class=\"desc-faq-q\"\u003eIs the 1336T-B040-AA-GM1-GT2EN-HA2 compatible with or interchangeable with other Allen Bradley VFD series?\u003c\/div\u003e\n\u003cdiv class=\"desc-faq-a\"\u003eThe 1336T-B040-AA-GM1-GT2EN-HA2 replacement for same-frame 40HP applications is most directly the Allen Bradley PowerFlex 400 (22C-D060A103) or the PowerFlex 70 (20AB040A0AYNANNN), both of which support EtherNet\/IP communications and operate on 480 VAC three-phase input at comparable current ratings. The 1336 PLUS II T-series shares significant parameter architecture with the earlier 1336 PLUS (1336F) series, so sites already familiar with that platform will find the transition manageable, though direct plug-and-play interchangeability requires verifying I\/O wiring, communication adapter compatibility, and bypass panel interface connections before commissioning. Competitor equivalents such as the ABB ACS550-01-072A-4 or Yaskawa A1000 CIMR-AU4A0038 can serve as functional replacements at the motor level, but network integration with Allen Bradley PLCs will require additional configuration work compared to staying within the Allen Bradley ecosystem.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"desc-faq-item\"\u003e\n\u003cdiv class=\"desc-faq-q\"\u003eHow do I know if my 1336T-B040-AA-GM1-GT2EN-HA2 is repairable or should be replaced outright?\u003c\/div\u003e\n\u003cdiv class=\"desc-faq-a\"\u003eIn most cases, 1336T-B040-AA-GM1-GT2EN-HA2 repair is viable unless the drive has sustained severe physical damage such as burned or exploded power modules, a cracked chassis, or corrosion-damaged PCB traces beyond the point of reliable restoration — conditions our free diagnostic process is specifically designed to assess. ALLEN BRADLEY 1336T-B040-AA-GM1-GT2EN-HA2 units presenting with common fault codes like F004, F009, F012, or communication errors are strong candidates for component-level repair, as these typically involve failed capacitors, gate drivers, or communication boards rather than catastrophic power stage destruction. If the IGBT power modules have failed shorted and caused collateral damage to the gate driver and control boards simultaneously, repair cost can approach replacement cost, and our technicians will provide a transparent cost comparison before proceeding. Units with water intrusion damage require case-by-case evaluation, as PCB contamination can cause intermittent faults that are difficult to fully remediate.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"desc-faq-item\"\u003e\n\u003cdiv class=\"desc-faq-q\"\u003eWhere can I get 1336T-B040-AA-GM1-GT2EN-HA2 repair service with a warranty?\u003c\/div\u003e\n\u003cdiv class=\"desc-faq-a\"\u003eFlexa Systems, based in Lewisville, TX, provides depot-level 1336T-B040-AA-GM1-GT2EN-HA2 repair service backed by a 2-year warranty on all repaired and refurbished units, covering both parts and labor from the date of shipment. Our standard turnaround is 5–7 business days from receipt of the failed unit, and we offer expedited service for critical production situations. We ship repaired drives nationwide, so facilities across the country can access the same level of component-level repair expertise without needing a local vendor — making us a practical answer for anyone searching for 1336T-B040-AA-GM1-GT2EN-HA2 repair near me regardless of location. If your unit is beyond repair, we also carry 1336T-B040-AA-GM1-GT2EN-HA2 for sale as tested refurbished stock, giving you an option to buy 1336T-B040-AA-GM1-GT2EN-HA2 USA-based inventory with the same warranty coverage and technical support.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"desc-faq-item\"\u003e\n\u003cdiv class=\"desc-faq-q\"\u003eWhere can I get 1336T-B040-AA-GM1-GT2EN-HA2 repair service with a warranty?\u003c\/div\u003e\n\u003cdiv class=\"desc-faq-a\"\u003eFlexa Systems provides professional 1336T-B040-AA-GM1-GT2EN-HA2 repair service from our facility in Lewisville, TX, serving customers nationwide. Standard turnaround is 5–7 business days from receipt and all repaired units ship with a 2-year warranty. Rush service (2–3 business days) is also available.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n  \u003cdiv class=\"desc-seo\"\u003eFlexa Systems specializes in ALLEN BRADLEY 1336T-B040-AA-GM1-GT2EN-HA2 variable frequency drive repair, supplying refurbished and new units backed by a 2-year warranty. All drives are load-tested before shipping. Serving industrial facilities nationwide from Lewisville, TX.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Repair Service","offer_id":54188184764691,"sku":"2100000012060","price":4600.0,"currency_code":"USD","in_stock":true},{"title":"Refurbished","offer_id":54188184797459,"sku":"2100000012060","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Brand New","offer_id":54188184830227,"sku":"2100000012060","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/1948\/5715\/files\/de70e4be7e66473e93c872adceca8193_default.jpg?v=1779350548","url":"https:\/\/flexa-systems.com\/products\/allen-bradley-1336t-b040-aa-gm1-gt2en-ha2","provider":"Flexa Systems","version":"1.0","type":"link"}